1E.1.27

Fendt 1E.1.27 – Engine Control Unit (ECU) / EDC 7: G001 - Battery 1 (12 VDC)

Issue description

Short circuit to the battery or a short to ground (earth). It can also trigger if the supply voltage falls outside the target range of 8 V to 18 V for longer than 10 seconds. When this fault is active, starting the tractor is not possible.

Applies to these machines

  • 309 Vario COM III
  • 310 Vario COM III
  • 311 Vario COM III
  • 312 Vario COM III
  • 922 Vario COM III
  • 924 Vario COM III
  • 927 Vario COM III
  • 930 Vario COM III
  • 933 Vario COM III
  • 936 Vario COM III
  • Fendt 200 Vario series (207, 208, 209, 210, 211)
  • Fendt 300 Vario series
  • Fendt 400 Vario series
  • Fendt 700 Vario series
  • Fendt 800 Vario series
  • Fendt 900 Vario series (e.g., 916, 920, 922, 924, 927, 930, 933, 936)

Check the cause

  1. Test battery voltage at the G001 battery terminals (should be approx. 12.8 VDC with ignition ON/engine OFF, ~8 VDC during starting, and 13.8-14 VDC when running)

  2. Check the 'Power supply +Ub' wiring harness between the G001 battery and the EDC control module for cable breaks, chafing, or short circuits to ground

  3. Inspect the battery terminals and main ground strap on the chassis (terminal 31) for corrosion or loose connections

Repair steps

  1. Disconnect Power

    Turn off the ignition and disconnect the negative terminal of the G001 battery to ensure safety while working on the electrical system.

  2. Repair Wiring

    If a short to ground or broken wire was found during the diagnostic phase in the EDC power supply circuit, repair or replace the damaged section of the wiring harness.

  3. Replace Battery

    If the battery fails a load test or cannot maintain the required 12.8 VDC resting voltage, remove the battery case and replace the G001 battery.

  4. Clean and Reconnect

    Clean the battery terminals and cable clamps with a wire brush. Reconnect the positive terminal first, followed by the negative terminal. Ensure connections are tight.

  5. Clear Fault Codes

    Connect the tractor to the FENDIAS / SERDIA diagnostic software and use 'SERDIA (delete error)' or 'clear fault' to restore normal starting functionality.

Parts you might need

(9)
  • 12 VDC Heavy Duty Tractor Battery

    SLI or EFB technology

  • OEM AGCO/Fendt Battery

    FX991604341

    100 Ah, 900 CCA - Common for smaller Vario models

  • OEM AGCO/Fendt Battery

    3931132M1

    AGCO FieldStart OEM battery

  • OEM AGCO/Fendt Battery

    3931020M1

    AGCO FieldStart OEM battery

  • OEM AGCO/Fendt Battery

    79037013

    AGCO FieldStart OEM battery

  • OEM AGCO/Fendt Battery

    79018975

    AGCO FieldStart OEM battery

  • Bosch T5 077 Battery

    2500092T50770

    180 Ah, 1000 CCA - Common for 800/900 series

  • Exide EA1000 Battery

    100 Ah

  • Varta H3 Battery

    100 Ah

Get help to fix this fault by requesting a quote

Browse other Fendt codes