Fendt 1E.1.27 – Engine Control Unit (ECU) / EDC 7: G001 - Battery 1 (12 VDC)
Issue description
Short circuit to the battery or a short to ground (earth). It can also trigger if the supply voltage falls outside the target range of 8 V to 18 V for longer than 10 seconds. When this fault is active, starting the tractor is not possible.
Applies to these machines
16 machines- 309 Vario COM III
- 310 Vario COM III
- 311 Vario COM III
- 312 Vario COM III
- 922 Vario COM III
- 924 Vario COM III
- 927 Vario COM III
- 930 Vario COM III
- 933 Vario COM III
- 936 Vario COM III
- Fendt 200 Vario series (207, 208, 209, 210, 211)
- Fendt 300 Vario series
- Fendt 400 Vario series
- Fendt 700 Vario series
- Fendt 800 Vario series
- Fendt 900 Vario series (e.g., 916, 920, 922, 924, 927, 930, 933, 936)
Check the cause
Test battery voltage at the G001 battery terminals (should be approx. 12.8 VDC with ignition ON/engine OFF, ~8 VDC during starting, and 13.8-14 VDC when running)
Check the 'Power supply +Ub' wiring harness between the G001 battery and the EDC control module for cable breaks, chafing, or short circuits to ground
Inspect the battery terminals and main ground strap on the chassis (terminal 31) for corrosion or loose connections
Repair steps
Disconnect Power
Turn off the ignition and disconnect the negative terminal of the G001 battery to ensure safety while working on the electrical system.
Repair Wiring
If a short to ground or broken wire was found during the diagnostic phase in the EDC power supply circuit, repair or replace the damaged section of the wiring harness.
Replace Battery
If the battery fails a load test or cannot maintain the required 12.8 VDC resting voltage, remove the battery case and replace the G001 battery.
Clean and Reconnect
Clean the battery terminals and cable clamps with a wire brush. Reconnect the positive terminal first, followed by the negative terminal. Ensure connections are tight.
Clear Fault Codes
Connect the tractor to the FENDIAS / SERDIA diagnostic software and use 'SERDIA (delete error)' or 'clear fault' to restore normal starting functionality.
Parts you might need
(9)12 VDC Heavy Duty Tractor Battery
SLI or EFB technology
OEM AGCO/Fendt Battery
FX991604341100 Ah, 900 CCA - Common for smaller Vario models
OEM AGCO/Fendt Battery
3931132M1AGCO FieldStart OEM battery
OEM AGCO/Fendt Battery
3931020M1AGCO FieldStart OEM battery
OEM AGCO/Fendt Battery
79037013AGCO FieldStart OEM battery
OEM AGCO/Fendt Battery
79018975AGCO FieldStart OEM battery
Bosch T5 077 Battery
2500092T50770180 Ah, 1000 CCA - Common for 800/900 series
Exide EA1000 Battery
100 Ah
Varta H3 Battery
100 Ah
Get help to fix this fault by requesting a quote