Fendt 3.1.06 – A004 Control Console: A004 - Control console — External 8.5 V fault
Issue description
The control console is not receiving its required 8.5-volt external power supply, or there is an internal failure within the console preventing the 8.5V circuit from operating. As a protective measure, the system automatically switches off the keypad / button panel, digital and analogue inputs, and LED actuation.
Applies to these machines
20 machines- 409 Vario
- 410 Vario
- 411 Vario
- 412 Vario
- 711 Vario
- 712 Vario
- 714 Vario
- 715 Vario
- 716 Vario
- 717 Vario
- 718 Vario
- 916 Vario
- 920 Vario
- 924 Vario
- 926 Vario
- 930 Vario
- Farmer 400 Vario
- Favorit 700 Vario
- Favorit 900 Vario
- Fendt 300, 400, 700, 800, and 900 Vario series (including COM III generation models)
Check the cause
Check fuses on the A013 fuse board, specifically the 8.5 V supply fuses (often listed as Fuse 5 or Fuse 9) and the CAN-Bus voltage supply fuses (F040, F041).
Inspect the wiring harness and connectors between the A013 fuse board and the A004 Control Console for any shorts to ground, corrosion, or open circuits.
Measure the voltage at the A004 console connector pins to confirm if the 8.5V supply is missing (indicating a wiring/fuse issue) or if the voltage is present but the console is failing to process it (indicating an internal console failure).
Repair steps
Power down and disconnect battery
Power down the tractor and disconnect the battery.
Remove interior trim panels
Remove the interior trim panels on the right-hand mudguard/armrest inside the cab to access the A004 Control Console.
Disconnect electrical harnesses
Carefully disconnect the electrical harness connectors (e.g., Connector X033) from the A004 Control Console.
Remove faulty console
Unbolt and remove the faulty A004 Control Console.
Install replacement console
Install the replacement control console and secure the mounting hardware.
Reconnect harnesses and reinstall panels
Reconnect the electrical harnesses and reinstall the cab trim panels.
Reconnect battery and calibrate
Reconnect the battery. Note: Depending on the tractor model and generation, the new console may require EOL (End of Line) programming or calibration via the FENDIAS diagnostic tool to pair it with the tractor's enhanced control ECU (A002).
Parts you might need
(4)A004 Control Console / Side Console ECU / Ergonomic Operator Control Panel
You MUST verify the exact part number using the tractor's specific chassis number. Alternatively, specialized agricultural electronics repair shops offer mail-in board-level repair services.
Control Console
G718701030201Left-hand console / operator control panel for certain 700/Vario models
Control Console
H210812131100Tractor Console for 200 series Vario
Control Console
F524810131020Tractor Console for Xylon series
Get help to fix this fault by requesting a quote