Fendt 4.1.42 – Transmission Control Unit: B014 - Hall sensor for accumulator shaft speed (partially also defined by 'Hydrostat') — Signal fault
Issue description
The control unit is not receiving a valid rotational speed or direction signal from the B014 Hall-effect sensor located on the hydrostatic accumulator/collecting shaft.
Applies to these machines
32 machines- 409 Vario
- 410 Vario
- 411 Vario
- 412 Vario
- 711 Vario
- 712 Vario
- 714 Vario
- 715 Vario
- 716 Vario
- 717 Vario
- 718 Vario
- 916 Vario
- 920 Vario
- 924 Vario
- 926 Vario
- 930 Vario
- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- Fendt 300 Vario (COM III)
- Fendt 400 Vario (COM III) / Farmer 400
- Fendt 700 Vario (COM III) / Favorit 700
- Fendt 800 Vario (COM III)
- Fendt 900 Vario (COM III) / Favorit 900
Check the cause
Test the connector at the B014 sensor to ensure it is receiving exactly 8.5 volts
Inspect the A013 fuse block (Fuse 1 or Fuse 16 depending on model) for a blown fuse, which causes a loss of the 8.5 V supply
Inspect the wiring harness between the B014 sensor and the Transmission ECU for chafing, breaks, or corrosion, particularly at the sensor connector
Repair steps
Power Down
Turn off the tractor and remove the key to ensure the transmission control circuit is unpowered.
Locate the Sensor
Locate the B014 Hall sensor on the hydrostatic transmission housing (accumulator/collecting shaft).
Verify Fuses
Check and replace the A013 fuse (Fuse 1 or 16) if blown. If the fuse blows again immediately upon key-on, there is a short in the wiring harness that must be repaired first.
Remove the Faulty Sensor
Disconnect the electrical harness from the B014 sensor. Unbolt and carefully remove the sensor from the transmission housing.
Install the New Sensor
Insert the replacement B014 sensor, ensuring any O-rings or seals are properly seated to prevent transmission fluid leaks. Torque the mounting bolt to OEM specifications.
Reconnect and Clear Codes
Reconnect the electrical harness. Turn on the ignition, access the tractor's terminal (Variotronic Ti), and clear the stored fault codes.
Test Drive
Operate the tractor to ensure the transmission shifts out of emergency mode and the fault code does not return.