4.1.E9

Fendt 4.1.E9 – A002 - ECU, enhanced control: Values for shift from range II to I outside tolerances

Issue description

The transmission control unit has detected that the parameters for shifting from speed range II to speed range I are outside of the acceptable tolerance window. This is typically caused by the B016 travel speed range detection sensor drifting out of calibration, failing, or losing its 8.5V reference voltage, or by incorrect EOL programming. The tractor will enter an auxiliary/emergency operation mode where shifting between ranges is only possible when completely stationary.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • Farmer 400 Vario series
  • Favorit 700 / 900 Vario series
  • 300, 400, 700, 800, 900, and 1000 Vario series (including COM III and S4 generations)

Check the cause

  1. Verify the 8.5V power supply to the B016 travel range detection sensor and check the corresponding fuse on the A013 fuse board (often Fuse 8 or Fuse 13, depending on the specific model year).

  2. Inspect the wiring harness and connector at the B016 sensor for corrosion, moisture, or breaks.

  3. Inspect the Y002 (travel range I) and Y003 (travel range II) solenoid valves to ensure they are receiving signals and are not mechanically jammed.

  4. Attempt to recalibrate the range shift mechanism using Calibration Code 4003 on the tractor's terminal.

Repair steps

  1. Bring tractor to a standstill

    Bring the tractor to a complete standstill, as range shifting is locked out while moving under this fault condition.

  2. Locate sensor

    Access the transmission control block and locate the B016 travel range detection sensor.

  3. Test harness and repair

    Disconnect the sensor and test the harness for the 8.5V reference signal and ground. Repair the harness or replace the blown A013 fuse if the voltage is missing.

  4. Execute calibration

    If the wiring is intact, connect a diagnostic tool or use the onboard terminal to execute Calibration Code 4003.

  5. Evaluate sensor

    If the calibration fails, or if the sensor values are erratic/drifting during the procedure, the B016 sensor is internally faulty and must be replaced.

  6. Replace sensor

    Remove the old B016 sensor and install the new OEM replacement.

  7. Perform EOL programming

    After installation, you must perform EOL programming/recalibration using Calibration Code 4003 so the A002 ECU can learn the new sensor's zero-positions and tolerances.

  8. Clear codes and test

    Clear the fault codes and test drive the tractor, shifting from Range II to Range I to verify the repair.

Parts you might need

(1)
  • Travel speed range detection sensor (B016) / Transmission speed sensor

    G350100970011

    Supersedes/interchanges with G931970020050, G350100970010, G916970020010

Get help to fix this fault by requesting a quote

Browse other Fendt codes