6.1.1B (Not 900)

Fendt 6.1.1B (Not 900) – EST control module (E-box): Actuation fault with the Y027 - Rear PTO speed 750 solenoid valve

Issue description

The system detects that the solenoid valve is not actuating properly, either due to an electrical fault (wiring/coil) or a mechanical seizure. As a result, the rear PTO cannot be engaged in the 750 RPM speed setting.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • Fendt Farmer 400 series (409, 410, 411, 412)
  • Fendt Favorit 700 / Fendt 700 Vario series (711, 712, 714, 716)
  • Fendt 800 Vario series (815, 817, 818)

Check the cause

  1. Perform Emergency Mode Test: Attempt to bypass the standard electrical speed selection by pressing and holding the 'Engage PTO' key in the cab for more than 5 seconds. If the PTO still cannot engage, it confirms the solenoid valve (Y027) is physically faulty or seized in the 'OFF' position.

  2. Inspect wiring harness and connectors leading to the Y027 solenoid valve for damaged pins, short to ground, or open circuit.

  3. Inspect the mechanical speed selector mechanism for binding or faults.

  4. Verify there are no concurrent signal faults at the Hall-effect speed sensors (B020, B021) on the rear PTO stub shaft, as a failed sensor can prevent actuation.

Repair steps

  1. Power Down

    Turn off the tractor, remove the key, and ensure hydraulic pressure in the PTO circuit is relieved.

  2. Locate the Valve

    Locate the Y027 solenoid valve on the rear PTO hydraulic control block.

  3. Electrical Testing

    Disconnect the electrical harness from the Y027 solenoid. Use a multimeter to check the resistance of the solenoid coil. If it reads open (infinite resistance) or shorted, the coil is dead.

  4. Valve Removal

    If the wiring is intact but the valve is seized or electrically failed, unbolt and remove the Y027 solenoid valve from the manifold. Be prepared to catch a small amount of hydraulic fluid.

  5. Installation

    Install the new solenoid valve, ensuring O-rings are properly seated and lubricated with clean hydraulic oil. Torque to OEM specifications.

  6. Reconnect and Clear

    Reconnect the electrical harness. Turn on the ignition and use the tractor's terminal to call up and clear the stored 6.1.1B fault code from the memory.

  7. Test Operation

    Start the tractor and engage the rear PTO at the 750 RPM setting to confirm normal operation.

Parts you might need

(1)
  • Rear PTO Speed Selection Solenoid Valve (Stage II / 750 RPM)

    Ensure you are ordering the valve for the 'single e-box' PTO block, as the Favorit 900 twin e-box uses a different valve arrangement.

Get help to fix this fault by requesting a quote