Fendt 6.1.B0 – A004 - ECU, control panel: CAN bus communication restricted / Initialisation error on the communication driver.
Issue description
The Rear PTO (Power Take-Off) becomes non-operational.
Applies to these machines
23 machines- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- Fendt 300 Vario (COM III)
- Fendt 400 Vario (COM III)
- Fendt 700 Vario (COM III)
- Fendt 800 Vario (COM III)
- Fendt 900 Vario (COM III)
- 916
- 920
- 924
- 926
- 930
- 933
- 936
Check the cause
Verify the voltage supply for the CAN-Bus by checking the A013 fuse board, specifically inspecting fuses F040 and F041. A blown fuse will drop communication to the A004 console.
Inspect the CAN bus wiring harness between the A004 Control Console and the A002 Enhanced Control ECU. Look for line discontinuities, chafed wires, or loose connector pins.
Check for concurrent fault codes like 1.1.9E or 1.1.9F (indicating a hard CAN communication failure between A002 and A004) or 3.1.01 through 3.1.06 (indicating internal RAM/EEPROM hardware failures in the console).
Repair steps
Connect diagnostic tool
Connect the FENDIAS diagnostic interface (or a compatible dealer-level tool like TEXA) to the tractor's diagnostic port.
Perform EOL programming
Perform End-Of-Line (EOL) reprogramming to re-flash or re-initialize the A004 control panel so it can re-establish proper CAN communication with the tractor's network.
Clear codes and test
After the EOL programming is complete, clear the fault memory and test the Rear PTO engagement to ensure functionality has returned.
Repair or replace A004 console
If EOL programming fails or the console is completely unresponsive due to internal circuit board failure, remove the A004 control console. Send it to an agricultural electronics specialist for board-level repair or replace it with a new/refurbished unit. Note: A replacement unit will still require EOL programming.
Parts you might need
(4)A004 Control Console
G718.970.071.020OEM part for 700/800 series. Remanufacturing/repair services are a common alternative.
A004 Control Console
G916.971.070.012OEM part for 900 series. Remanufacturing/repair services are a common alternative.
A004 Control Console
G916.971.070.026OEM part for 900 series. Remanufacturing/repair services are a common alternative.
A004 Control Console
G411.971.070.017OEM part for 400 series. Remanufacturing/repair services are a common alternative.
Get help to fix this fault by requesting a quote