6.1.E0

Fendt 6.1.E0 – A002 - ECU, enhanced control: Checksum error parameter current control for speed selector

Issue description

The EEPROM memory inside the control module has detected corrupted or mismatched calibration data regarding the current control parameters for the speed/range selector.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • 411 Vario COM III
  • 412 Vario COM III
  • 413 Vario COM III
  • 414 Vario COM III
  • 415 Vario COM III
  • 712 Vario COM III
  • 714 Vario COM III
  • 716 Vario COM III
  • 718 Vario COM III
  • 818 Vario COM III
  • 820 Vario COM III
  • Fendt 300 Vario (COM III)
  • Fendt 400 Vario (COM III)
  • Fendt 700 Vario (COM III)
  • Fendt 800 Vario (COM III)
  • Fendt 900 Vario (COM III and earlier Favorit 900 series)

Check the cause

  1. Check for Accompanying Bus Faults: Verify if there are other CAN bus communication errors (e.g., 0.0.14, 0.0.15) which might indicate a wiring or power issue rather than an internal ECU memory failure.

  2. Check Power Supply: Ensure the voltage supply to the CAN-Bus on fuse board A013 is intact (specifically check fuses F040 and F041, which supply the A002 module).

  3. Check ECU Load via Terminal: Using the tractor's Variotronic Ti terminal (A008), navigate to the Diagnostics Menu. Check the 'Load counter of the A002 - ECU, enhanced control.' If the ECU is unloaded, a value of around 22000 is indicated; if the load is increasing, a lower value is shown.

Repair steps

  1. Connect diagnostic tool

    Connect the AGCO 2x4 CANUSB Diagnostic Tool to the tractor's diagnostic port (ensure connection to the G and K bus ports).

  2. Launch diagnostic software

    Launch the FENDIAS diagnostic software and open the EOL (End of Line) programming module.

  3. Select programming mode

    Select 'Programming Development' and input the tractor's chassis number to build the connection.

  4. Run EOL programming

    Run a new EOL programming sequence for the A002 Enhanced Control ECU to overwrite the corrupted speed selector parameters.

  5. Perform hard reset

    Wait for the programming to finish (this can take 15-20 minutes). Once the software prompts that devices have been switched into bootloader mode, perform a hard reset: Turn the ignition OFF, wait 15 seconds, and turn the ignition ON.

  6. Clear fault memory and verify

    Clear the fault memory. If the EOL programming fails to take, or if the 6.1.E0 fault code immediately returns, the EEPROM chip inside the A002 E-box has suffered a hardware failure and the ECU must be replaced.

Parts you might need

(3)
  • A002 ECU, Enhanced Control (E-Box / Comfort ECU)

    G725.970.070.019

    A replacement A002 ECU must be flash-programmed (EOL programming) via FENDIAS before installation to match the specific tractor's transmission and comfort features.

  • A002 ECU, Enhanced Control (E-Box / Comfort ECU)

    G816.970.070.046

    A replacement A002 ECU must be flash-programmed (EOL programming) via FENDIAS before installation to match the specific tractor's transmission and comfort features.

  • A002 ECU, Enhanced Control (E-Box / Comfort ECU)

    G737.970.070.035

    A replacement A002 ECU must be flash-programmed (EOL programming) via FENDIAS before installation to match the specific tractor's transmission and comfort features.

Get help to fix this fault by requesting a quote

Browse other Fendt codes