Fendt 7.1.4A – A004 Control Console: A004 - "Active" key (only NA version) — Plausibility error, key has been pressed for more than 30 seconds.
Issue description
The system has detected that the "Active" button on the armrest control console has been continuously depressed for over 30 seconds. This plausibility error indicates a physically stuck button, a collapsed microswitch, or an internal short circuit, which disables the Front PTO functions.
Applies to these machines
49 machines- 409 Vario
- 410 Vario
- 411 Vario
- 412 Vario
- 711 Vario
- 712 Vario
- 714 Vario
- 715 Vario
- 716 Vario
- 717 Vario
- 718 Vario
- 916 Vario
- 920 Vario
- 924 Vario
- 926 Vario
- 930 Vario
- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- Fendt 300 Vario (COM III)
- Fendt Farmer 400 / 400 Vario (COM III)
- 409
- 410
- 411
- 412
- Fendt Favorit 700 / 700 Vario (COM III)
- 711
- 712
- 714
- 716
- Fendt 800 Vario (COM III)
- 815
- 817
- 818
- 820
- Fendt Favorit 900 / 900 Vario (COM III)
- 916
- 920
- 924
- 926
- 930
Check the cause
Inspect the 'Active' key on the A004 armrest control console for physical sticking, dirt, debris, or lack of tactile click.
Connect the FENDIAS diagnostic tool and monitor the live state of the 'Active' key to see if it shows as 'pressed' without physical actuation.
Check the wiring harness and connectors leading to the A004 control console for any signs of damage or moisture.
Look for associated CAN bus communication faults (e.g., between A004 and A002 Enhanced Control ECU) which might indicate a broader failure.
Repair steps
Clean the Keypad
Attempt to clean around the 'Active' key using electrical contact cleaner and compressed air to dislodge any debris causing the button to stick. If the button frees up, clear the code and retest.
Disconnect Power
If the button has internally failed, turn off the tractor and disconnect the battery before disassembling the armrest.
Remove the A004 Console
Remove the retaining screws and trim panels on the right-hand armrest to access the A004 control console.
Disconnect Harnesses
Carefully unplug the CAN bus and power connectors from the bottom of the A004 unit.
Replace or Repair
Remove the faulty A004 control console. It is common practice to send the A004 unit to a specialized agricultural electronics repair center to have the internal microswitches replaced.
Reinstallation
Install the new or repaired A004 control console and reconnect all wiring harnesses.
Calibration
According to Fendt service documentation, a complete calibration must generally be carried out after the replacement of the control console (A004). Use FENDIAS to perform the necessary calibrations.
Clear Codes & Test
Reconnect the battery, clear the stored 7.1.4A fault code, and test the Front PTO engagement to verify the repair.
Parts you might need
(1)A004 Control Console / Armrest Keypad ECU
Exact part numbers vary significantly based on the specific tractor model, chassis number, and configuration. Ensure the replacement console is the correct 'NA version' (North American).
Get help to fix this fault by requesting a quote