Fendt 8.3.17 – Rear EPC (Electronic Power Control) control module (A005 or A014): Supply voltage (Battery Voltage / Ub 30) is greater than 18 Volts
Issue description
The system has detected that the supply voltage (Battery Voltage / Ub 30) is greater than 18 Volts. Control is terminated and locked to prevent electrical damage to the module and solenoids.
Applies to these machines
15 machines- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- Farmer 400 Vario series
- Favorit 700 Vario series
- Favorit 900 Vario series (916, 920, 924, 926, 930)
- COM III Vario Series (300, 400, 700, 800, and 900 Vario models)
Check the cause
Verify battery voltage at the terminals while the tractor is running; readings climbing above 15V–18V indicate an alternator voltage regulator failure (overcharging cause)
Check if the tractor was recently jump-started using a 24V system, which would immediately trigger this overvoltage code
If battery voltage tests normal (12.6V resting, ~14.2V running), disconnect the harness at the Rear EPC control module (A014) and probe the constant power supply pin (Ub 30) to check for a severe harness short
If physical voltage at the module pin is normal (12V-14V) but the ECU still reports >18V, verify if the internal voltage sensing circuit of the EPC module has failed (module failure cause)
Repair steps
Address the Overcharge
If the alternator is outputting >18V, immediately shut down the tractor to prevent frying other ECUs.
Replace the Voltage Regulator / Alternator
Disconnect the battery negative terminal. Remove the serpentine belt, disconnect the electrical connections to the alternator, and unbolt the unit. Install a new alternator or replace the voltage regulator pack on the rear of the existing alternator.
Inspect for Collateral Damage
Check all fuses on the A013 printed circuit board (specifically F040, F041) and test other tractor functions.
Clear Codes
Reconnect the battery, start the tractor, and verify the charging voltage is now stable at ~14.2V. Use the tractor's multi-display terminal or the FENDIAS diagnostic tool to clear the 8.3.17 fault code and unlock the rear power lift controls.
Parts you might need
(2)Alternator / Voltage Regulator
Exact OEM part number varies depending on the specific engine (e.g., Deutz vs. MAN). Always match the amperage rating of the original alternator.
Rear EPC Control Module (ECU A014 / A005) / E-box rear power lift module
Only replace this if the alternator tests perfectly fine but the module's internal voltage sensor is shorted.