Fendt 9.1.55 – ECU, enhanced control (A002): Spool valve fault – Overvoltage (> 45 volts)
Issue description
The system detects an abnormally high voltage spike (over 45V) at the Y019 auxiliary control valve. As a safety measure, the valve automatically moves into the neutral position and locks out.
Applies to these machines
16 machines- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- Fendt 300 Vario (COM III)
- Fendt 400 Vario (COM III) / Farmer 400 (e.g., 409, 410, 411, 412)
- Fendt 700 Vario (COM III) / Favorit 700 (e.g., 711, 712, 714, 716)
- Fendt 800 Vario (COM III) (e.g., 815, 817, 818)
- Fendt 900 Vario (COM I, II, III) / Favorit 900 (e.g., 916, 920, 924, 926, 930)
Check the cause
System Voltage Check: Test the tractor's charging system and alternator regulator. A failing alternator regulator can send massive voltage spikes through the electrical system.
Wiring Harness Inspection: Inspect the wiring harness leading to the Y019 valve (often located on the right side of the transmission/central control block) for chafed wires that could be shorting to a higher voltage source.
CAN Bus & Power Supply Check: Verify the power supply for the CAN bus on printed circuit board A013. Check fuses F040, F041, and F047 to ensure they are intact and not bypassed with incorrect ratings.
Connector Inspection: Disconnect the Y019 valve (Connector X330) and check for corrosion, water ingress, or damaged pins that could cause electrical shorts.
Repair steps
Disconnect Power
Turn off the tractor and disconnect the battery to prevent further electrical damage.
Resolve Voltage Issues
If the alternator was found to be overcharging during diagnostics, replace the alternator/voltage regulator before proceeding, or the new valve will be damaged.
Repair Wiring
Repair any chafed or shorted wires in the harness leading to the Y019 valve.
Replace the Valve
If the tractor's voltage is normal (12V/24V) and the wiring is intact, the internal circuit board of the Y019 valve has likely failed. Relieve all hydraulic pressure, disconnect connector X330, unbolt the spool valve head/assembly, and install the new auxiliary control valve with new O-rings.
Calibration
After replacing an electric spool valve, the new valve must be calibrated/taught to the tractor's ECU using the FENDIAS diagnostic software or the tractor's EOL (End of Line) programming terminal.
Parts you might need
(5)Auxiliary Control Valve / Hydraulic Spool Valve (Bosch SB 23 LS-EHS)
G931962026105Y019 valve is specifically programmed for its position in the valve stack (usually position 5 / brown). Ensure you are ordering the correct slice for the front power lift or the specific rear remote it controls.
Auxiliary Control Valve / Hydraulic Spool Valve (Bosch SB 23 LS-EHS)
G931962025202Y019 valve is specifically programmed for its position in the valve stack (usually position 5 / brown). Ensure you are ordering the correct slice for the front power lift or the specific rear remote it controls.
Auxiliary Control Valve / Hydraulic Spool Valve (Bosch SB 23 LS-EHS)
R917005756Y019 valve is specifically programmed for its position in the valve stack (usually position 5 / brown). Ensure you are ordering the correct slice for the front power lift or the specific rear remote it controls.
Valve head/solenoid
F411151600010Y019 valve is specifically programmed for its position in the valve stack (usually position 5 / brown). Ensure you are ordering the correct slice for the front power lift or the specific rear remote it controls.
Valve head/solenoid
321/G411150600040Y019 valve is specifically programmed for its position in the valve stack (usually position 5 / brown). Ensure you are ordering the correct slice for the front power lift or the specific rear remote it controls.