A.1.12

Fendt A.1.12 – Enhanced Control ECU (A002): Spool valve fault, valve 1 — Supply voltage < 8 volts.

Issue description

The valve cannot operate safely with low voltage and automatically moves into the neutral position. Valve operation for this circuit becomes unavailable.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • Farmer 400 Vario
  • Favorit 700 Vario
  • Favorit 900 Vario
  • 700, 800, and 900 Vario COM III series

Check the cause

  1. Measure supply voltage at the Y015 valve connector (X326) to confirm if it is dropping below 8 volts.

  2. Inspect fuses F040 and F041 and the power supply on circuit board A013.

  3. Check CAN bus wiring (G-bus connections) at connector X641 (CAN high) and X642 (CAN low) for the Y015-Y019 valve block.

  4. Inspect the wiring harness for high resistance, corroded pins, chafed wires, or poor ground connections between the A002 ECU, A013 circuit board, and X326 valve connector.

Repair steps

  1. Resolve Wiring/Voltage Issues

    If the voltage at connector X326 is below 8V, repair the damaged wiring harness, clean the ground points, or replace the blown F040/F041 fuses.

  2. Replace the Valve

    If the tractor is supplying proper voltage (typically 12V) to the connector but the A.1.12 code remains active, the internal electronics of the Y015 spool valve have failed. The valve must be replaced.

  3. Access the Valve Block

    The valve block is typically located on the right side of the tractor, near the central control block (ZSB). You may need to remove the right entrance step footplate or access flap to reach it.

  4. Install New Valve

    Swap out the defective Y015 valve.

  5. EOL Programming

    According to Fendt documentation, the auxiliary control valves are programmed for their specific positions (e.g., position 1 / yellow) in the End-of-Line (EOL) program. You will need to use the FENDIAS diagnostic software to program the new valve to the tractor.

  6. Clear Codes

    Use the tractor's terminal or the FENDIAS tool to clear the stored A.1.12 fault code and verify normal operation.

Parts you might need

(1)
  • Auxiliary Control Valve / Electro-hydraulic Spool Valve (Position 1, Yellow)

    Component ID: Y015. Specific OEM part numbers vary heavily by exact chassis serial number and must be sourced via dealer using the tractor's VIN.

Get help to fix this fault by requesting a quote