A.1.1F

Fendt A.1.1F – A002 - ECU (Enhanced Control Unit): Spool valve fault, valve 1

Issue description

The system reports that the 'Setpoint message is missing or not plausible' or the 'Configuration message is missing or not plausible'. This indicates a communication or electrical failure at the valve, typically caused by a CAN-BUS error, a potentiometer fault, or a PWM signal failure.

Applies to these machines

  • 411 Vario COM III
  • 412 Vario COM III
  • 413 Vario COM III
  • 414 Vario COM III
  • 415 Vario COM III
  • 712 Vario COM III
  • 714 Vario COM III
  • 716 Vario COM III
  • 718 Vario COM III
  • 818 Vario COM III
  • 820 Vario COM III
  • Farmer 400 Vario
  • Favorit 700 Vario
  • Favorit 900 Vario
  • COM III Generation Vario 300 series
  • COM III Generation Vario 400 series
  • COM III Generation Vario 700 series
  • COM III Generation Vario 800 series
  • COM III Generation Vario 900 series
  • 412
  • 716
  • 818
  • 920
  • 924
  • 930

Check the cause

  1. Identify the Y015 valve on the rear hydraulic stack (Position 1, usually marked with a yellow decal or cap).

  2. Inspect the electrical connector at the Y015 valve for moisture, corrosion, or backed-out pins.

  3. Verify the CAN-BUS wiring harness integrity between the A002 ECU and the Y015 valve. A break in the CAN lines will cause the message missing fault.

  4. Check the supply voltage to ensure the valve is receiving proper baseline power.

  5. Connect the FENDIAS diagnostic tool to see if the valve is recognized on the valve bus. If recognized but the fault remains, the valve's internal electronics have failed.

Repair steps

  1. Preparation

    Park the tractor on a level surface, lower all implements, turn off the engine, and actuate the hydraulic levers/terminal to relieve all residual hydraulic pressure. Disconnect the battery.

  2. Removal

    Disconnect the electrical harness from the Y015 (yellow) spool valve.

  3. Unbolt the Valve

    Remove the tie-rod bolts securing the valve stack. Carefully separate the Y015 valve from the hydraulic block. Note: Have a catch pan ready, as residual hydraulic oil will spill.

  4. Installation

    Install the new auxiliary control valve, ensuring all O-rings between the valve slices are new and properly seated to prevent internal/external leaks.

  5. Reassembly

    Torque the valve stack bolts to OEM specifications and reconnect the electrical harness.

  6. Programming

    Connect the FENDIAS software and use the EOL (End of Line) program to configure the new valve to 'Position 1' so the A002 ECU recognizes it on the CAN bus.

  7. Testing

    Reconnect the battery, start the tractor, clear the A.1.1F fault code, and test the hydraulic function.

Parts you might need

(2)
  • Electronic Auxiliary Control Valve / Spool Valve (Position 1 / Yellow)

    Exact part numbers vary heavily based on the specific tractor model and chassis serial number break. Look up in Fendt EPC. Typically Bosch Rexroth SB23 or SB33 series.

  • O-rings

    Ensure all O-rings between the valve slices are new.

Get help to fix this fault by requesting a quote