A.1.1F

Fendt A.1.1F – ECU, enhanced control, electric auxiliary control valves: Spool valve fault, valve 1 (Y015) — Setpoint message is missing or not plausible.

Issue description

The electronic control unit is not receiving a valid command signal (setpoint) or configuration message for the first auxiliary spool valve. This is typically caused by a communication error on the CAN bus, a missing configuration message, or a faulty potentiometer/PWM signal from the operator's joystick or crossgate lever. As a safety measure, the system locks the valve and it automatically moves into the neutral position.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • Farmer 400 and 400 Vario (COM III)
  • Favorit 700 and 700 Vario (COM III)
  • Favorit 900 and 900 Vario (COM III)
  • 300 Vario and 800 Vario series

Check the cause

  1. Access the 'SPOOL VALVES 1 - 4 setpoint / actual value display' on the tractor's terminal to see if the tractor is registering any input from the controls

  2. Check for a potentiometer or PWM fault. The issue is frequently caused by a failing joystick or crossgate lever rather than the valve itself

  3. Inspect the wiring harness and CAN bus lines leading to the Y015 valve. The specific connection for Valve 1 (Y015) is Connector X326 (pins 23, 24, and 26)

  4. Verify that the auxiliary control valve is still correctly programmed for position 1 in the EOL (End-of-Line) program

Repair steps

  1. Resolve Input Faults

    If the diagnostic display shows a potentiometer/PWM fault, recalibrate the joystick/crossgate lever. If calibration fails, replace the faulty control lever.

  2. Repair Wiring

    If CAN bus communication is broken, repair the wiring harness at Connector X326.

  3. Valve Replacement

    If the wiring and joystick are functioning properly but the valve's internal electronics cannot process the setpoint message, the Y015 spool valve must be replaced. Note: The Y015 valve is the 1st control valve located on the underside of the central control block. To access it, you generally need to unscrew the right step and pull the right auxiliary tank outwards.

  4. Reteach Valves (EOL Programming)

    After replacing the valve, you must use the tractor's terminal or FENDIAS diagnostic software to 'Reteach existing valves.' Select the 1st valve (yellow) and assign it as 'Hydraulic spool valve AUX 1' so the ECU recognizes the new component on the bus.

Parts you might need

(1)
  • Auxiliary control valve, position 1 (Yellow marker) / Control valve SB 23 LS - EHS

    Bosch Rexroth/Fendt standard valve. Standard flow rate 100 l/min.

Get help to fix this fault by requesting a quote

Browse other Fendt codes