A.1.23

Fendt A.1.23 – Electrical Valves / VENDI: Y016 - Spool valve fault, valve 2 — Supply voltage > 18 volts

Issue description

Overvoltage detection. The internal electronics of the auxiliary control valve (Valve 2, Y016) are measuring a power supply voltage exceeding 18 volts. As a built-in safety consequence, the system forces the valve to move into the neutral position and disables its operation to prevent uncontrolled hydraulic functions.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • Farmer 400 Vario series
  • Favorit 700 Vario series
  • Favorit 900 Vario series
  • 300 Vario series
  • 400 Vario series
  • 500 Vario series
  • 700 Vario series
  • 800 Vario series
  • 900 Vario series

Check the cause

  1. System Voltage Check: Measure the tractor's overall system voltage at the battery and alternator while the engine is running. If the alternator voltage regulator has failed, it could be sending >18V to the entire system.

  2. Wiring & Connector Inspection: Locate Valve 2 (Y016) at the rear hydraulic block. Disconnect its electrical connector (Connector X327). Inspect the pins for corrosion, moisture ingress, or damage.

  3. Pin Voltage Test: With the tractor ignition on, use a multimeter to test the supply voltage pins on the tractor-side of connector X327. If the voltage reads a normal 12-14V, the wiring and ECU are fine, meaning the valve's internal circuit board has failed and is falsely reporting an overvoltage.

  4. CAN Bus Check: Verify the CAN High and CAN Low lines between the enhanced control ECU and the valve to ensure there are no shorts to power.

Repair steps

  1. Relieve hydraulic pressure

    Turn off the tractor, lower all implements to the ground, and relieve all hydraulic system pressure.

  2. Disconnect electrical connector

    Disconnect the X327 electrical connector from the Y016 (Valve 2) spool valve.

  3. Clean valve block area

    Clean the area around the hydraulic valve block thoroughly to prevent contamination.

  4. Extract faulty valve section

    Unbolt the tie rods/mounting bolts securing the spool valve stack and carefully extract the faulty Y016 valve section.

  5. Install replacement valve

    Install the replacement selective control valve section, ensuring new O-rings are used between the slices. Torque the mounting bolts to the manufacturer's specification (e.g., 30 Nm for Bosch SB1 type manifolds).

  6. Reconnect lines and connector

    Reconnect the hydraulic lines and the X327 electrical connector.

  7. Perform EOL programming

    Connect the FENDIAS / Serdia diagnostic tool. The new valve must be registered to the CAN bus via End-of-Line (EOL) programming and assigned to position 2.

  8. Clear codes and test

    Clear the fault codes and test the hydraulic functions.

Parts you might need

(11)
  • AGCO/Fendt Selective Control Valve

    G414962020034

    Fitment: 200, 300, 500, and 700 Vario SCR/S4 series

  • Pilot electrovalve

    F931962030160

    Fitment: 800 and 900 Vario SCR / Profi / Power series

  • Pilot electrovalve

    R917008341

    Bosch Rexroth OEM for F931962030160

  • Bosch Rexroth hydraulic distributor valve section

    0521610563

    Fitment: Farmer 400, 700, 800, and 900 Vario series

  • Bosch SB1 Type Aux Control Unit

    0521610000
  • Bosch SB1 Type Aux Control Unit

    0521610003
  • Bosch SB1 Type Aux Control Unit

    0521610005
  • Bosch SB1 Type Aux Control Unit

    0521610007
  • Bosch SB1 Type Aux Control Unit

    0521610008
  • Bosch SB1 Type Aux Control Unit

    0521610011
  • Bosch SB1 Type Aux Control Unit

    0521610017

Get help to fix this fault by requesting a quote

Browse other Fendt codes