Fendt A.1.24 – Enhanced Control ECU (A002): Y016 - Auxiliary control valve 2 Spool valve fault
Issue description
The main piston travel is too short due to a drop in control pressure below 22 bar. The system forces the valve into the neutral position to prevent uncontrolled movements.
Applies to these machines
22 machines- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- Farmer 400 Vario series
- Favorit 700 series
- Favorit 900 series
- 700 Vario series
- 800 Vario series
- 900 Vario series
- 916
- 920
- 924
- 926
- 930
Check the cause
Check hydraulic oil temperature, as low temperatures can cause sluggish piston movement and trigger the fault
Test control pressure at test port M5 to ensure it does not drop below 22 bar during valve actuation
Test the diaphragm accumulator for failure, which can cause momentary pressure drops
Inspect the RV7 relief valve and pilot pressure supply circuit
Repair steps
Warm-Up & Clear
Bring the tractor up to normal operating temperature to thin the hydraulic oil. Clear the fault codes via the terminal and actuate the blue remote (Valve 2) to see if the code returns.
Pressure Verification
If the code returns, install a hydraulic pressure gauge at test port M5. Actuate the valve. If the pressure drops below 22 bar, the issue is with the pilot pressure supply (investigate the diaphragm accumulator or RV7 valve).
Valve Inspection
If the control pressure at M5 remains steady above 22 bar but the A.1.24 code still logs, the internal mechanics of the Y016 spool valve are failing (the main piston is physically sticking or the internal position sensor is failing to read full travel).
Valve Replacement
Remove the right-hand step and pull the right auxiliary tank outwards to access the central control block. The Y016 valve is the 2nd control valve on the underside of the block. Replace the valve.
EOL Programming
After installing a new electric spool valve, it must be registered to "Position 2 (blue)" on the CAN bus using Fendt's EOL (End of Line) programming software (FENDIAS).
Parts you might need
(6)Auxiliary Control Valve / Directional Spool Valve
Position 2
Fendt Directional Valve
G716961022021Common on newer 700/800/900 Vario SCR/S4/Gen6 models
Fendt Directional Valve
G117961021025High-precision hydraulic control variant
Fendt Change Valve / Spool Valve
F716961020240Block 2 Flow Valve
F514950160200Common on older Farmer 400 and Favorit 700/900 series
Spool Valve Quick Release Coupling
G718960110100If the external coupler is leaking and causing pressure drops
Get help to fix this fault by requesting a quote