Fendt A.1.27 – ECU, enhanced control (A002): Internal position sensor fault
Issue description
The internal position pickup sensor within the spool valve's electronic actuator has failed or is sending an implausible signal. For safety, the system forces the valve to move into the neutral position, and auxiliary valve operation for this circuit is disabled.
Applies to these machines
24 machines- 409 Vario
- 410 Vario
- 411 Vario
- 412 Vario
- 711 Vario
- 712 Vario
- 714 Vario
- 715 Vario
- 716 Vario
- 717 Vario
- 718 Vario
- 916 Vario
- 920 Vario
- 924 Vario
- 926 Vario
- 930 Vario
- Farmer 400 series
- Favorit 700 series
- Favorit 900 series
- Fendt 300 Vario series
- Fendt 400 Vario series
- Fendt 700 Vario series
- Fendt 800 Vario series
- Fendt 900 Vario series
Check the cause
Verify the Code: Read out the KWP code using the SERDIA / Fendias diagnostic tool to confirm the fault is isolated to the Y016 position sensor.
Check Voltage & CAN Bus: Ensure the issue is not a wiring harness problem. Check the X327 connector at Valve 2.
Inspect for Contamination: Check the hydraulic filters and fluid condition.
Repair steps
Depressurize the System
Remove all system pressure from the hydraulic circuit before loosening any bolts. Personal injury or equipment damage could result.
Disconnect Electronics
Unplug the X327 electrical connector from the Y016 (blue) valve.
Remove the Valve
Unbolt the auxiliary control valve from the valve stack.
Install the New Valve
Mount the replacement valve. To prevent distorting the valve body, tighten the mounting bolts in steps of 25% using a crisscross pattern.
EOL Programming
The new auxiliary control valve must be programmed for 'position 2' using the Fendt EOL (End of Line) program via the diagnostic tool.
System Flush
If the failure was accompanied by oil contamination, flush the hydraulic system and replace the hydraulic oil and filters.
Parts you might need
(1)Auxiliary Control Valve (Position 2 / Blue)
Always order using the specific tractor chassis number as valve stacks vary by exact build. Must be electronically assigned to Position 2 (Y016) via the EOL programming software after installation.
Get help to fix this fault by requesting a quote