A.1.2B

Fendt A.1.2B – Spool Valves 1 - 4 / Electrical Valves: Spool valve fault, valve 2 — Floating position is not reached.

Issue description

The electro-hydraulic auxiliary spool valve in position 2 (designated in Fendt schematics as Y016, color-coded blue) is failing to reach its commanded floating position. As a safety measure, the system automatically forces the valve to move into the neutral position and locks it to prevent uncontrolled hydraulic functions.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • Fendt 300 Vario (COM III)
  • Fendt Farmer 400
  • Fendt 400 Vario (COM III)
  • Fendt Favorit 700
  • Fendt 700 Vario (COM III)
  • Fendt 800 Vario (COM III)
  • Fendt Favorit 900
  • Fendt 900 Vario (COM III)
  • 916
  • 920
  • 924
  • 926

Check the cause

  1. Verify if the valve was manually overridden (manual actuation deflects it from its neutral position).

  2. Inspect hydraulic filters and oil condition for contamination that can cause the main piston inside the spool valve to jam.

  3. Check the CAN II bus wiring (specifically pins 4 and 5) to valve Y016.

  4. Verify the supply voltage to the valve is between 8 Volts and 18 Volts.

  5. Check for overvoltage spikes (> 45V).

  6. Test for a failing internal position pickup sensor or an end-stage error in the pilot control solenoid.

Repair steps

  1. Relieve Hydraulic Pressure

    Ensure the tractor is turned off, the implement is lowered, and all hydraulic pressure is relieved from the system before servicing the valve block.

  2. Locate Valve Y016

    Locate the auxiliary control valve block. Identify Valve 2 (Y016), which is typically color-coded blue.

  3. Inspect Wiring Harness

    Disconnect the electrical connector to Valve 2. Inspect the pins for corrosion, moisture, or damage. Clean and reconnect if necessary, then clear the code to see if it returns.

  4. Remove the Spool Valve

    If the wiring is sound and the valve is mechanically binding or internally failing to reach the float position, the spool valve assembly must be removed. Unbolt the valve section from the hydraulic manifold stack.

  5. Install Replacement Valve

    Install the new electro-hydraulic spool valve section, ensuring all O-rings are properly seated to prevent leaks.

  6. EOL Programming

    According to Fendt service documentation, a newly installed auxiliary control valve must be programmed for its specific position (Position 2) using the FENDIAS EOL (End of Line) diagnostic software.

  7. Test Operation

    Clear the fault codes and actuate the valve via the multifunction armrest to confirm the floating position is now successfully reached.

Parts you might need

(2)
  • Electro-Hydraulic Auxiliary Spool Valve (Position 2 / Blue)

    A complete OEM part number for the specific Y016 valve assembly was not found in the available service literature.

  • Fendt Spool Valve Quick Release Coupling - Short Type

    G718960110100

    If the quick-release coupling on the valve is damaged.

Get help to fix this fault by requesting a quote