Fendt A.1.36 – A002 ECU (Enhanced Control / Variotronic TI): Spool valve fault, valve 3 - Magnet output stage fault within spool valve
Issue description
The electronic control unit integrated into the spool valve has detected an electrical failure in the output stage that drives the valve's internal pilot solenoid magnet. As a safety measure, the valve automatically moves into the neutral position and remains set there.
Applies to these machines
16 machines- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- Farmer 400 Vario: 409, 410, 411, 412
- Favorit / Vario 700: 711, 712, 714, 715, 716, 717
- Favorit / Vario 800: 815, 817, 818, 820
- Favorit / Vario 900: 916, 918, 920, 924, 926, 930
- 300 Vario (COM III)
Check the cause
Identify the Correct Valve: Locate valve Y017. Fendt color-codes their auxiliary valves; Y017 is Position 3 and is designated by the Red color marker.
Wiring & Connector Inspection: Check the wiring harness and the connector (X328) at the Y017 valve for corrosion, pushed pins, or moisture ingress.
Voltage & CAN Bus Check: Verify that the valve is receiving proper supply voltage and CAN bus communication.
Mechanical Binding: Ensure the main piston is not jammed due to oil contamination.
Repair steps
Depressurize the System
Ensure the tractor is off, the implement is lowered, and hydraulic pressure is fully relieved from the system.
Disconnect Electronics
Unplug the X328 electrical connector from the red Y017 auxiliary control valve.
Component Replacement
Because the magnet output stage is internal to the valve's electronic actuator head, the electronic head (or the entire valve section) must be replaced. Remove the tie rods/mounting bolts holding the valve stack and carefully extract the Y017 section.
Reassembly
Install the new valve section using new O-rings/seals between the slices. Torque the valve block tie rods to OEM specifications.
Programming / EOL
The new auxiliary control valve must be programmed for 'Position 3' using the Fendt EOL (End of Line) program via the FENDIAS diagnostic tool. If it is not taught into the CAN bus network, it will not function.
Testing
Clear the fault codes, start the tractor, and test the red auxiliary circuit for proper operation.
Parts you might need
(8)Auxiliary Control Valve Section / Electrohydraulic Spool Valve (Valve 3)
G816960021012Bosch Rexroth SB23 LS Series equivalent
Auxiliary Control Valve Section / Electrohydraulic Spool Valve (Valve 3)
G816960021013Bosch Rexroth SB23 LS Series equivalent
Auxiliary Control Valve Section / Electrohydraulic Spool Valve (Valve 3)
G816960021014Bosch Rexroth SB23 LS Series equivalent
Auxiliary Control Valve Section / Electrohydraulic Spool Valve (Valve 3)
G816960021015Bosch Rexroth SB23 LS Series equivalent
Auxiliary Control Valve Section / Electrohydraulic Spool Valve (Valve 3)
G816960021016Bosch Rexroth SB23 LS Series equivalent
Auxiliary Control Valve Section / Electrohydraulic Spool Valve (Valve 3)
0521610086Bosch Rexroth Reference
Auxiliary Control Valve Section / Electrohydraulic Spool Valve (Valve 3)
0521610010Bosch Rexroth Reference
Seal Kit
F716961020020SB23-EHS section sealing kit