A.1.47

Fendt A.1.47 – Electrical Valves (E-box): Spool valve fault, valve 4 (Auxiliary control valve)

Issue description

Internal position sensor fault. As a safety measure, the affected valve automatically moves into the neutral position.

Applies to these machines

  • 411 Vario COM III
  • 412 Vario COM III
  • 413 Vario COM III
  • 414 Vario COM III
  • 415 Vario COM III
  • 712 Vario COM III
  • 714 Vario COM III
  • 716 Vario COM III
  • 718 Vario COM III
  • 818 Vario COM III
  • 820 Vario COM III
  • Fendt 300 Vario COM III
  • Fendt 400 Vario COM III
  • Fendt 700 Vario COM III
  • Fendt 800 Vario COM III / 820 Vario greentec
  • Fendt 900 Vario COM III

Check the cause

  1. Verify the Fault on the Multi-Display: Read the error code from the multi-display. Note that simply cancelling or clearing the fault code from the terminal does not fix the issue; the fault will reappear the next time the tractor is started if the underlying sensor issue remains.

  2. Check Manual Actuation: Ensure that manual actuation of the valve does not have any play. The slider must be able to return to the middle (neutral) position by itself.

  3. Inspect for Oil Contamination: Check the hydraulic fluid condition and filters to ensure debris isn't causing the valve to stick, which could interfere with sensor readings.

Repair steps

  1. Relieve Hydraulic Pressure

    Before servicing any hydraulic components, ensure the tractor is turned off, implements are lowered, and all hydraulic pressure is relieved from the system.

  2. Locate Valve 4

    Access the rear electronic spool valve block (E-box) and identify auxiliary control valve 4 (Y018).

  3. Inspect the Sensor and Wiring

    Check the wiring harness and connector going to the internal position sensor on valve 4 for any breaks, corrosion, or loose connections.

  4. Replace the Faulty Component

    Because the fault is an internal position sensor failure, the sensor itself or the entire solenoid spool valve section typically needs to be replaced if the sensor cannot be serviced independently.

  5. Clean the System

    If any contamination is found in the valve bore during removal, clean it thoroughly. Debris can prevent proper seating and cause immediate failure of the new component.

  6. Clear the Code

    After installing the new valve/sensor, use the tractor's terminal to clear the stored A.1.47 fault code. Each stored code must be cleared individually.

Parts you might need

(6)
  • AGCO/Fendt Solenoid Valve

    F414962020040

    Fits a wide range of Vario models including 200, 300, 500, 700, 800, 900, and 1000 series

  • Fendt OEM Solenoid Valve

    G931150600050

    Fits 700, 800, 900, and 1000 Vario series

  • AGCO/Fendt Solenoid Valve

    F931962030150

    Fits 800 and 900 Vario series; Bosch reference R917004223

  • Solenoid Operated Valve

    G312100600110

    Fits 1000 Vario S4 and older Farmer 300 series

  • Fendt OEM Directional Valve

    G737960020033
  • Fendt OEM Directional Valve

    G737960020034

Get help to fix this fault by requesting a quote

Browse other Fendt codes