Fendt A.1.4F – A002 E-box: Fault with Y018 - Auxiliary control valve (Spool Valve 4)
Issue description
Setpoint message is missing or not plausible, or a CAN-BUS error with the valves. This typically indicates a potentiometer or PWM fault, causing the system to lock the valves and force Valve 4 into the neutral position.
Applies to these machines
15 machines- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- 400 Vario Series
- 700 Vario Series
- 800 Vario Series
- 900 Vario Series (including 916, 920, 924, 926, 930)
Check the cause
Verify CAN Bus communication to ensure Valve 4 is registered on the bus.
Check supply voltage at the valve (system forces neutral if voltage is below 8V, above 18V, or spikes over 45V).
Test the potentiometer and PWM signals for Valve 4 to ensure plausible setpoint/actual values.
Inspect the valve actuator mechanically to ensure it is not stuck, can return to neutral, and can reach the float position.
Check for an EEPROM inconsistency or fault while storing/loading data in the A002 E-box.
Repair steps
Connect Diagnostic Tool
Connect a compatible multi-brand electronic diagnostic tool (such as a TEXA Navigator TXTs) to the tractor's dedicated diagnostic socket.
System Scan
Perform a complete scan of all electronic systems (e.g., using the TGS3 function) to see if the A.1.4F error is currently active or stored.
Inspect the Hydraulic Valve Bus
Access the wiring diagram through your diagnostic tool to identify all components electrically connected to Spool Valve 4 (Y018).
Inspect Wiring and Connections
Physically inspect the wiring harness, pins, and connectors between the A002 E-box and Valve 4 for corrosion, breaks, or shorts that would interrupt the PWM signal or CAN communication.
Test the Valve Actuation Module
If the wiring is intact, check the valve actuation electronics for common failure symptoms: operation no longer possible, failure to react to the float position, or sporadic blocking.
Repair or Replace
If the electronics in the valve are faulty, remove the valve actuation module and either send it to a specialized agricultural electronics repair facility or replace the valve assembly entirely.
Clear Codes and Calibrate
After repairing or replacing the valve, clear the fault codes from the A002 E-box and perform any necessary End-Of-Line (EOL) programming or valve calibrations to register the new component on the CAN bus.
Parts you might need
(5)Valve Actuation Module
G210.962.022Also supersedes/applies to variants: G210.962.022.011, G210.962.022.012, G210.962.022.013, G210.962.022.014, G210.962.022.015, G210.962.022.016
Solenoid Operated Valve
G312100600110Directional Spool Valve
G117961021025Hydraulic Valve Block
J312301150040Spool Valve Quick Release Coupling
G718960110100Fits 200, 300, 400, 500, 700, 800, 900 Vario series
Get help to fix this fault by requesting a quote