A.1.4F

Fendt A.1.4F – A002 E-box: Fault with Y018 - Auxiliary control valve (Spool Valve 4)

Issue description

Setpoint message is missing or not plausible, or a CAN-BUS error with the valves. This typically indicates a potentiometer or PWM fault, causing the system to lock the valves and force Valve 4 into the neutral position.

Applies to these machines

  • 411 Vario COM III
  • 412 Vario COM III
  • 413 Vario COM III
  • 414 Vario COM III
  • 415 Vario COM III
  • 712 Vario COM III
  • 714 Vario COM III
  • 716 Vario COM III
  • 718 Vario COM III
  • 818 Vario COM III
  • 820 Vario COM III
  • 400 Vario Series
  • 700 Vario Series
  • 800 Vario Series
  • 900 Vario Series (including 916, 920, 924, 926, 930)

Check the cause

  1. Verify CAN Bus communication to ensure Valve 4 is registered on the bus.

  2. Check supply voltage at the valve (system forces neutral if voltage is below 8V, above 18V, or spikes over 45V).

  3. Test the potentiometer and PWM signals for Valve 4 to ensure plausible setpoint/actual values.

  4. Inspect the valve actuator mechanically to ensure it is not stuck, can return to neutral, and can reach the float position.

  5. Check for an EEPROM inconsistency or fault while storing/loading data in the A002 E-box.

Repair steps

  1. Connect Diagnostic Tool

    Connect a compatible multi-brand electronic diagnostic tool (such as a TEXA Navigator TXTs) to the tractor's dedicated diagnostic socket.

  2. System Scan

    Perform a complete scan of all electronic systems (e.g., using the TGS3 function) to see if the A.1.4F error is currently active or stored.

  3. Inspect the Hydraulic Valve Bus

    Access the wiring diagram through your diagnostic tool to identify all components electrically connected to Spool Valve 4 (Y018).

  4. Inspect Wiring and Connections

    Physically inspect the wiring harness, pins, and connectors between the A002 E-box and Valve 4 for corrosion, breaks, or shorts that would interrupt the PWM signal or CAN communication.

  5. Test the Valve Actuation Module

    If the wiring is intact, check the valve actuation electronics for common failure symptoms: operation no longer possible, failure to react to the float position, or sporadic blocking.

  6. Repair or Replace

    If the electronics in the valve are faulty, remove the valve actuation module and either send it to a specialized agricultural electronics repair facility or replace the valve assembly entirely.

  7. Clear Codes and Calibrate

    After repairing or replacing the valve, clear the fault codes from the A002 E-box and perform any necessary End-Of-Line (EOL) programming or valve calibrations to register the new component on the CAN bus.

Parts you might need

(5)
  • Valve Actuation Module

    G210.962.022

    Also supersedes/applies to variants: G210.962.022.011, G210.962.022.012, G210.962.022.013, G210.962.022.014, G210.962.022.015, G210.962.022.016

  • Solenoid Operated Valve

    G312100600110
  • Directional Spool Valve

    G117961021025
  • Hydraulic Valve Block

    J312301150040
  • Spool Valve Quick Release Coupling

    G718960110100

    Fits 200, 300, 400, 500, 700, 800, 900 Vario series

Get help to fix this fault by requesting a quote

Browse other Fendt codes