A.1.56

Fendt A.1.56 – A057 - ECU, steering controller (Auto-Guide): An EEPROM reading fault has occurred.

Issue description

The steering controller's internal memory (EEPROM) has failed to read its stored data or parameters. This is an internal logic/memory error within the control unit.

Applies to these machines

  • 411 Vario COM III
  • 412 Vario COM III
  • 413 Vario COM III
  • 414 Vario COM III
  • 415 Vario COM III
  • 712 Vario COM III
  • 714 Vario COM III
  • 716 Vario COM III
  • 718 Vario COM III
  • 818 Vario COM III
  • 820 Vario COM III
  • Fendt 300 Vario COM III series
  • Fendt 400 Vario COM III series
  • 411
  • 412
  • 413
  • 414
  • 415
  • Fendt 700 Vario COM III series
  • 712
  • 714
  • 716
  • 718
  • Fendt 800 Vario COM III series
  • 820 Vario greentec
  • Fendt 900 Vario COM III series

Check the cause

  1. Verify the A057 ECU is receiving proper and stable voltage, as low voltage or power spikes can cause temporary EEPROM read/write errors.

  2. Check software and calibration by attempting EOL (End-Of-Line) programming using the FENDIAS dealer diagnostic tool to re-flash the EEPROM data.

Repair steps

  1. Connect diagnostic tool

    Connect the FENDIAS diagnostic laptop to the tractor's diagnostic port.

  2. Navigate to module

    Navigate to the A057 Steering Controller module.

  3. Execute EOL programming

    Execute the EOL programming procedure to rewrite the EEPROM parameters.

  4. Clear codes and cycle ignition

    Clear the fault codes and cycle the tractor's ignition.

  5. Test system

    Test the Auto-Guide system. If the A.1.56 fault code returns, replace the box, as the EEPROM chip has suffered a permanent hardware failure.

  6. Replace A057 ECU

    If replacement is necessary, physically locate the A057 ECU, disconnect the wiring harnesses, and swap in the new module.

  7. Calibrate new ECU

    Perform EOL programming and steering angle sensor (WAS) calibration on the newly installed A057 ECU so it can communicate with the tractor's CAN bus.

Parts you might need

(1)
  • A057 ECU, Steering Controller (Auto-Guide)

    Must be programmed (EOL) via FENDIAS to match the specific tractor's chassis and hydraulic steering valve configuration. Third-party mail-in repair services are an alternative option.

Get help to fix this fault by requesting a quote

Browse other Fendt codes