Fendt A.1.5B – A057 - ECU, steering controller (Auto-Guide): Invalid EEPROM parameters for the steering control regulator
Issue description
The steering controller has detected an invalid data set within its EEPROM, preventing the Auto-Guide automated steering system from functioning correctly.
Applies to these machines
17 machines- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- Fendt 200 Vario (including V / F / P variants)
- Fendt 300 Vario COM III
- Fendt 400 Vario COM III
- Fendt 700 Vario COM III
- Fendt 800 Vario COM III
- Fendt 900 Vario COM III
Check the cause
Check system voltage to verify the power supply to the A057 ECU, as drops below 10.1 VDC can cause EEPROM reading/writing errors
Check for accompanying EEPROM codes (such as A.1.55, A.1.56, or A.1.57) which usually point to a hard internal failure of the module
Inspect the wiring harness and connections to the A057 steering controller for corrosion or damage that could cause data corruption or voltage drops
Repair steps
Connect diagnostic tool
Connect the FENDIAS diagnostic laptop to the tractor.
Perform EOL programming
Perform EOL (End of Line) programming on the A057 steering controller to re-flash the module and overwrite the corrupted EEPROM parameters with a valid data set.
Replace module
If the FENDIAS tool cannot successfully write to the EEPROM, the A057 ECU has suffered a hardware failure and must be replaced.
Recalibrate system
Perform a steering valve and steering angle sensor calibration (Calibration code 2401 / 2403) before the Auto-Guide system will engage.
Parts you might need
(1)A057 ECU, Steering Controller (Auto-Guide)
0 054 124 100 000Auto-Guide Standard VBS kit (includes ECU and TopDock terminal). Requires EOL programming via FENDIAS upon installation.