A.1.A0

Fendt A.1.A0 – A002 - ECU, enhanced control: EEPROM fault while storing

Issue description

The control module has failed to save or write set values to its internal EEPROM memory, resulting in a loss of enhanced features when operating the hydraulic valves.

Applies to these machines

  • 411 Vario COM III
  • 412 Vario COM III
  • 413 Vario COM III
  • 414 Vario COM III
  • 415 Vario COM III
  • 712 Vario COM III
  • 714 Vario COM III
  • 716 Vario COM III
  • 718 Vario COM III
  • 818 Vario COM III
  • 820 Vario COM III
  • Fendt 300 Vario (COM III)
  • Fendt Farmer 400 Vario (e.g., 409, 410, 411, 412)
  • Fendt / Favorit 700 Vario (e.g., 711, 712, 714, 716)
  • Fendt 800 Vario (e.g., 815, 817, 818)
  • Fendt / Favorit 900 Vario (e.g., 916, 920, 924, 926, 930)

Check the cause

  1. Verify the voltage supply to the CAN-Bus on fuse board A013, specifically checking fuses F040 and F041.

  2. Inspect the wiring harness and connectors going to the A002 E-box for corrosion, loose pins, or damage.

  3. Use the FENDIAS diagnostic program or the Variotronic TI terminal to check for secondary bus faults or communication errors that might be interrupting the memory storage process.

Repair steps

  1. Attempt Reprogramming

    Attempt an End-Of-Line (EOL) reprogramming or flash programming of the A002 ECU using the FENDIAS tool.

  2. Replace the ECU

    If the EEPROM cannot be overwritten or the EOL reprogramming fails, the internal memory is permanently corrupted, and the A002 E-box must be replaced.

  3. System Calibration

    A complete calibration must be carried out after the replacement of the A002 Enhanced control ECU. This includes calibrating all connected sensors, the crossgate lever, and the transmission/actuator units using the FENDIAS software.

Parts you might need

(1)
  • A002 - ECU, enhanced control (E-box)

    Ensure you are ordering the correct version (e.g., twin e-box vs. single e-box) for your specific chassis range. Look up the exact part number using the machine's specific VIN/Chassis number.

Get help to fix this fault by requesting a quote

Browse other Fendt codes