A.1.A1

Fendt A.1.A1 – E-box (A002 - ECU, enhanced control): E-box — EEPROM fault while loading

Issue description

This indicates a memory read error within the control unit. The ECU is unable to load its stored set values or enhanced control parameters from its internal EEPROM memory during startup or operation. Consequences can result in restricted operating possibilities, loss of enhanced features, or auxiliary control valves moving to the neutral position and locking.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • Fendt 300 Vario (COM III)
  • Fendt Farmer 400 / 400 Vario (COM III)
  • Fendt Favorit 700 / 700 Vario (COM III)
  • Fendt Favorit 800 / 800 Vario (COM III)
  • Fendt Favorit 900 / 900 Vario (COM III)

Check the cause

  1. Verify the voltage supply to the A002 E-box by checking the CAN-Bus voltage supply on fuse board A013 (specifically fuses F040 and F041).

  2. Connect the FENDIAS diagnostic tool and attempt to perform an End-of-Line (EOL) programming or reload the data record.

  3. Check the hardware version to determine if the tractor has an older E-box with a physical EPROM chip (requires physical replacement) or a newer flash-programmable unit.

  4. Assess module status: if the E-box cannot be reflashed, or if the EEPROM fault immediately returns after a successful flash, the internal memory is permanently corrupted or physically damaged.

Repair steps

  1. Disconnect Power

    Turn off the tractor and disconnect the battery to prevent electrical spikes.

  2. Locate the E-box

    Access the electronics box area (typically located in the right-hand side console/cab area, depending on the specific Vario model).

  3. Remove the Defective Module

    Carefully disconnect the multi-pin wiring harnesses from the A002 E-box. Unbolt the module from its mounting bracket.

  4. Install the Replacement/Repaired Module

    Mount the new or remanufactured E-box and securely reconnect all wiring harnesses.

  5. Restore Power

    Reconnect the tractor's battery.

  6. End-of-Line (EOL) Programming

    Connect the FENDIAS diagnostic system and perform EOL programming to register the module to the tractor's CAN bus, configure the connected valves, and calibrate the crossgate lever/joystick (Calibration code "1001").

Parts you might need

(8)
  • E-box / ECU, enhanced control (A002)

    G725970070014

    Fits models 411-415, 712-718, 818-820. Always order strictly by the tractor's chassis number.

  • E-box / ECU, enhanced control (A002)

    G701970070032

    Always order strictly by the tractor's chassis number.

  • E-box / ECU, enhanced control (A002)

    F701.970.070.032

    Always order strictly by the tractor's chassis number.

  • E-box / ECU, enhanced control (A002)

    G395970100042

    Fits GT 300 series. Always order strictly by the tractor's chassis number.

  • E-box / ECU, enhanced control (A002)

    F718.970.071.067

    Always order strictly by the tractor's chassis number.

  • E-box / ECU, enhanced control (A002)

    F816.970.150.045

    Always order strictly by the tractor's chassis number.

  • E-box / ECU, enhanced control (A002)

    F816.970.150.046

    Always order strictly by the tractor's chassis number.

  • E-box / ECU, enhanced control (A002)

    G312.970.070.014

    Always order strictly by the tractor's chassis number.

Get help to fix this fault by requesting a quote