Fendt A.1.C6 / C7 / C8 / C9 / CA – A004 Control Console: A004 Control console — CAN-bus fault
Issue description
CAN-bus communication failure or loss of signal involving the A004 Control Console, resulting in a complete loss of functions and display from the control console.
Applies to these machines
24 machines- 409 Vario
- 410 Vario
- 411 Vario
- 412 Vario
- 711 Vario
- 712 Vario
- 714 Vario
- 715 Vario
- 716 Vario
- 717 Vario
- 718 Vario
- 916 Vario
- 920 Vario
- 924 Vario
- 926 Vario
- 930 Vario
- Farmer 400 Vario
- Favorit 700 Vario
- Favorit 900 Vario
- 300 Vario series
- 400 Vario series
- 700 Vario series
- 800 Vario series
- 900 Vario series
Check the cause
Check the A013 printed circuit board (fuse board) for loss of voltage supply to the CAN-bus
Inspect fuses F040 and F041 on the A013 fuse board, as these directly supply power to the CAN-bus for the A004 control console
Check CAN-bus wiring and connections between the A002 EST Control Module (e.g., Pin 26, Connector X031) and the A004 Side/Control Console for interruptions, short circuits to earth, or corroded pins
Test the A013 fuse board for internal failures or burned-out traces if fuses are intact but power is not reaching the console
Repair steps
Disconnect power
Turn off the tractor ignition and disconnect the battery to prevent electrical shorts.
Inspect and replace fuses
Locate the A013 printed circuit board (fuse board) and inspect fuses F040 and F041. Replace them if they are blown. Reconnect power and test the console.
Access wiring harness
If the fuses are intact, access the wiring harness connecting the A002 Enhanced Control ECU (typically located in the cab on the right mudguard behind a panel) and the A004 Control Console.
Inspect and clean connectors
Disconnect the wiring harness connectors and inspect the pins for corrosion, moisture, or damage. Clean the contacts with electrical contact cleaner and secure the connections.
Perform continuity test
Perform a continuity test on the CAN-bus wiring between the A002 and A004 modules. Repair or replace the wiring harness if a break or short to ground is found.
Replace defective component
If the wiring and fuses are fully functional, the fault lies within either the A013 fuse board or the A004 Control Console itself. Replace the defective component.
Perform post-repair calibration
If the A004 Control Console is replaced, you must perform EOL (End of Line) programming and calibration using the FENDIAS diagnostic tool to pair the new console with the tractor's system and restore valve/joystick operations.
Parts you might need
(3)A004 Control Console / Armrest Control Unit
Generic Part
A013 Printed Circuit Board / Fuse Board
Generic Part
Microfuses
Standard automotive fuses for positions F040, F041