Fendt B.1.BO – A002 ECU: Read Error During Teach-in
Issue description
The system has detected an issue related to the Variotronic TI headland management system, specifically a read error during a Teach-in program run. The A002 Enhanced Control Unit is unable to correctly read the programming sequence, which renders the automated sequence functionality (such as lifting/lowering implements or engaging the PTO) non-operational.
Applies to these machines
6 machines- Farmer 400 Vario Series
- Favorit 700 Series
- Favorit 900 Series
- 700 Vario Series (COM III)
- 800 Vario Series (COM III)
- 900 Vario Series (COM III)
Check the cause
Use the tractor's onboard diagnostic interface to call up stored fault codes and confirm that B.1.B0 is present
Switch the tractor's ignition completely off and then on again to power cycle the system, which can sometimes clear temporary communication glitches
Check for other active fault codes in the B.1.xx range, particularly communication errors (e.g., B.1.21, B.1.22, B.1.23, B.1.24) or memory function errors (e.g., B.1.B4) to provide additional context
Repair steps
Reload EOL programming
Have a certified Fendt technician use proprietary FENDIAS diagnostic software to reload the EOL (End-of-Line) programming in the A002 Enhanced Control Unit.
Replace A002 ECU
If reloading the software does not resolve the read error, the fault lies within the hardware of the A002 ECU itself. Replace the Enhanced Control Unit.
Parts you might need
(3)OEM part number example. Must verify exact fitment using the AGCO Parts Catalog and tractor serial number.
A002 ECU / Enhanced Control Unit (400/700/900 Vario)
G718970071067OEM part number example. Must verify exact fitment using the AGCO Parts Catalog and tractor serial number.
- A002 ECU / Enhanced Control Unit (828 Vario)F836200010020
OEM part number example. Must verify exact fitment using the AGCO Parts Catalog and tractor serial number.
Get help to fix this fault by requesting a quote