Fendt X810 – EMR2: Diagnostics Socket Running Characteristics Reg. B - EMR
Issue description
This fault code indicates a communication error within the CAN bus network, specifically on the data line connecting the diagnostic socket to the Engine Management Regulation (EMR2) control unit. This disruption in the 'Reg. B' engine control network prevents proper diagnostic communication and can lead to reduced engine performance.
Applies to these machines
5 machines- 300 Vario
- 400 Vario
- 700 Vario
- 800 Vario
- 900 Vario
Check the cause
Check total CAN bus resistance at the diagnostic socket (should be approximately 60 Ohms)
Inspect the 120 Ohm terminating resistors located on Circuit Board A013 and Actuator Unit A009
Inspect the EMR2 ECU and its connectors for visible damage, corrosion, or loose connections
Repair steps
Verify fault code
Confirm that fault code X810 is active or stored in the tractor's diagnostic memory.
Test CAN bus resistance
Turn off ignition and disconnect the battery. Measure resistance between the CAN-H and CAN-L pins at the diagnostic socket. A healthy system will read approximately 60 Ohms.
Isolate wiring or resistor faults
If resistance is ~120 Ohms, one terminating resistor is missing; check Circuit Board A013 and Actuator Unit A009 individually for 120 Ohms. If both read 120 Ohms, inspect the wiring harness between the main CAN bus and the undetected component. If resistance is near 0 Ohms (short circuit), disconnect CAN users one by one to locate the short and inspect wiring for pinched or damaged insulation. If resistance is very high or open (OL), inspect wiring for breaks and check main junction points and connectors for the EMR2 ECU, circuit board A013, and actuator unit A009.
Inspect and test EMR2 ECU
If wiring and terminating resistors test correctly, visually inspect the EMR2 ECU. Use Fendt SERDIA software for internal fault testing, or substitute with a known good ECU to confirm the diagnosis.
Replace faulty components
Replace any identified faulty wiring, terminating resistors, circuit boards, or the EMR2 ECU.
Clear codes and verify
Reconnect the battery, clear all fault codes using the diagnostic system, and operate the tractor to ensure the fault does not return.
Parts you might need
(7)CAN Bus Terminating Resistor
Generic 120 Ohm Resistor. Typically integrated into the circuit board or actuator unit.
- Circuit Board (A013)F725970160030
Fuse circuit board, Printed circuit board. Verify the correct part number for your specific tractor model and serial number.
Circuit Board (A013)
72611285Supersedes F725970160030. Verify the correct part number for your specific tractor model and serial number.
- Circuit Board (A013)F260970160190
Verify the correct part number for your specific tractor model and serial number.
- Circuit Board (A013)H199860100120
Verify the correct part number for your specific tractor model and serial number.
- Actuator Unit (A009)G931100970012
Vario actuator unit. Verify the correct part number for your specific tractor model and serial number.
EMR2 ECU
Engine Control Unit, EMR2 Controller. Part number is specific to engine and tractor configuration.