Fendt Y035 – ECU EMR2: EMR Actuator Out of Allowed Range
Issue description
The Electronic Engine Control (EMR) actuator is operating outside of its permissible range, meaning its actual position does not match the position commanded by the engine control unit. This discrepancy can lead to improper engine function. A difference of more than 10% between the target and actual control travel triggers this fault.
Applies to these machines
5 machines- Fendt 300 Vario
- Fendt 400 Vario
- Fendt 700 Vario
- Fendt 800 Vario
- Fendt 900 Vario
Check the cause
Cycle the tractor's ignition off and on to see if the fault clears, as the error may disappear if the actuator's current returns to the normal range
Visually and mechanically inspect the EMR actuator's control rod for smooth and unrestricted movement, checking for any binding or obstruction
Use Fendt's SERDIA diagnostic software to check the actuator's feedback and target positions
Inspect the wiring harness between the EMR actuator and the EMR2 ECU for signs of damage, corrosion, or loose connections
Check the voltage supply to the EMR2 ECU
Repair steps
Perform initial diagnostics
Complete all visual, mechanical, and electrical diagnostic checks to rule out issues with wiring, control rod movement, or the ECU itself.
Replace EMR actuator
If diagnostic checks point to a faulty actuator, replace it with a new unit.
Clear fault codes and verify
Use the FENDIAS diagnostic system to clear the fault code memory and ensure the new actuator is functioning correctly.
Parts you might need
(1)- Electric Actuator / EMR 2 ActuatorF718202710080
Associated with the EMR2 engine control system on various Fendt Vario tractor models.
Get help to fix this fault by requesting a quote