Iveco 145 – Engine Control Unit (ECU) / EDC (Electronic Diesel Control): Fault of control circuit of the fan relay No. 1
Issue description
An electrical fault (such as an open circuit, a short to ground, or a short to battery voltage) in the wiring or the coil of the primary cooling fan relay, preventing the engine control module from commanding the cooling fan to turn on.
Applies to these machines
3 machines- Iveco Daily
- Iveco Stralis
- Iveco Trakker
Check the cause
Perform an active actuation test using a diagnostic scanner to listen for the relay clicking and clutch engaging
Check the main engine compartment fuse box for blown cooling fan fuses (often F2 or F11)
Test the continuity of the fan relay coil to ensure it is not open or short-circuited
Check the wiring harness continuity between the EDC connector (e.g., pin A39) and the relay socket
Repair steps
Disconnect Power
Turn off the ignition and disconnect the negative battery terminal to prevent electrical shorts during testing.
Locate the Relay
Locate the cooling fan relay 1 in the vehicle's main fuse/relay box (typically located in the engine compartment; often designated as R1 or R5).
Inspect the Socket
Remove the relay and inspect the socket terminals for signs of melting, corrosion, or pushed-out pins.
Test/Replace the Relay
Use a multimeter to test the resistance across the relay's control coil pins. If the coil is open (infinite resistance) or shorted, the relay is defective and must be replaced.
Harness Repair
If the relay tests fine, use a multimeter to trace the control wire from the relay block back to the EDC harness. Repair any chafed insulation or broken wires causing a short/open circuit.
Reassembly and Clearing
Install a known-good relay, reconnect the battery, and use your diagnostic scanner to clear the 0145 fault code.
Verification
Run the engine up to operating temperature or use the scanner's active test function to verify that the fan engages at the correct temperature threshold without triggering the code.
Parts you might need
(2)Radiator Fan Relay / Cooling Fan Relay 1
4653768512V Systems - e.g., Iveco Daily
Radiator Fan Relay / Cooling Fan Relay 1
9844401724V Systems - e.g., Stralis/Trakker