JCB C132E: Left Turn Indicator Output Short-Circuited
Issue description
The left turn indicator output is experiencing a short circuit, which may cause improper operation of the left turn signal. This issue affects the electrical circuit responsible for the left turn indicator.
Check the cause
The wiring associated with the left turn indicator output
Connections related to the left turn indicator output
The component identified by this code
Repair steps
Inspect
Inspect the wiring associated with the left turn indicator output for damage, wear, or exposed conductors.
Test
Test the connections related to the left turn indicator output for continuity and proper insulation.
Repair or Replace
Repair or replace the affected circuit or component identified by this code as necessary.