JCB P0629 – ECU: Global Fuel Pump Malfunction - Short to Battery

Issue description

The Engine Control Unit (ECU) has detected a high voltage condition in the fuel lift pump's control circuit, indicating a continuous voltage supply likely caused by a short to the battery. The commanded signal from the ECU does not match the feedback signal it is receiving. This malfunction affects the proper operation of the fuel pump and can lead to severe engine performance issues, including a reduction to only 60% of available engine torque, engine stalling, or a complete failure to start.

Applies to these machines

  • 1400B
  • 1550B
  • 1600B
  • 1700B
  • 214
  • 215
  • 216
  • 217
  • 3C
  • 3CX
  • 3D
  • 4C
  • 4CN
  • 4CX
  • 520
  • 526
  • 531
  • 535
  • 536
  • 540
  • 225
  • 225T
  • 260
  • 260T
  • 280
  • 300
  • 300T
  • 320T
  • 330

Check the cause

  1. Visually inspect the wiring harness and connectors associated with the fuel lift pump and relay for chafed, burnt, or broken wires, paying close attention to areas near hot exhaust components.

  2. Disconnect relevant connectors and inspect pins for water, oil, or debris contamination, ensuring they are properly seated and locked.

  3. Check for any damaged or loose machine earth (ground) connections.

  4. Inspect all fuses related to the fuel system to ensure none are blown.

  5. Test the fuel lift pump relay for correct activation and continuity.

  6. Measure the voltage at the fuel pump using a multimeter; excessive voltage when commanded on confirms a short to battery. Check the control signal from ECU pin 40 (Fuel Lift Pump Relay Drive).

Repair steps

  1. Disconnect power

    Always disconnect the machine's battery before starting any electrical repairs.

  2. Repair wiring and connectors

    Repair or replace any damaged sections of the wiring harness. Clean corroded connectors or replace them if they are damaged.

  3. Replace fuel pump relay

    If the fuel pump relay is found to be faulty during testing (e.g., stuck in the 'on' position), replace it, as this is a common cause of this fault code.

  4. Replace fuel lift pump

    If the wiring and relay are confirmed to be in good working order, the fuel lift pump may be drawing too much current due to an internal failure. Replace the fuel lift pump assembly.

  5. Check Engine Control Unit (ECU)

    As a last resort, if all other possibilities have been exhausted, inspect the ECU driver circuit for internal faults.

  6. Clear codes and test

    Reconnect the battery, clear the fault codes using a suitable diagnostic tool, and operate the machine to ensure the fault does not return.