JCB P0685 – ECM: Main Relay Unexpected Low State
Issue description
The Engine Control Module (ECM) has detected an open or malfunctioning circuit for its own power relay. The ECM regularly monitors the voltage in the control circuit that powers it. When the ECM detects a low-voltage or no-voltage condition at a time when the circuit should be energized (such as when the ignition key is turned on), it logs this fault. This indicates a loss of reliable power to the engine's computer, which halts all engine management functions like fuel injection and ignition timing, resulting in a failure to start.
Applies to these machines
5 machines- JCB 135 Skidsteer Loader
- JCB 444 engine machines
- JCB 448 engine machines
- Tracked excavators (Tier 4i / T4F)
- Wheeled excavators (Tier 4i / T4F)
Check the cause
Use a diagnostic scan tool to confirm P0685 is the active fault and note any accompanying codes.
Visually inspect the main relay, its socket, and the associated wiring harness for signs of corrosion, melted plastic, burnt insulation, or loose connectors (especially near the battery and fuse box).
Inspect fuses related to the ECM or main relay circuit for blown fuses.
Listen for an audible click from the relay when the ignition is turned to the 'ON' position.
Using a digital multimeter, check for constant battery voltage at the primary input terminal of the relay.
Check the secondary input terminal to verify it receives power when the ignition key is turned on.
With the relay energized, measure the voltage at the ECM's power input pin (should be approximately 12V ± 0.5V).
Verify the relay is receiving a battery voltage signal, a ground signal, and an input signal from the ignition switch.
With the relay de-energized, perform a continuity test on the power supply circuit to the ECM to check for high or infinite resistance indicating an open circuit.
Repair steps
Address simple electrical faults
Replace any blown fuses found during inspection. Clean any corrosion present on connectors or the relay socket thoroughly. Ensure all battery cables and electrical connections are tight.
Replace the main relay
If the relay fails the actuation test (no click) or shows internal failure during multimeter testing, replace it with a new unit. This is the most common solution.
Repair wiring harness
If visual inspection or continuity checks reveal damaged, burnt, or broken wires, repair or replace the affected section of the wiring harness. Ensure all repairs are insulated and protected from the elements.
Inspect and test ignition switch
If the electrical portion of the ignition switch fails to send the 'on' signal to the relay, test the switch and replace it if necessary.
Reprogram or replace ECM
If the relay, fuses, and wiring are all confirmed to be in good working order but the fault persists, the issue may be an internal failure of the ECM's power control circuit or a software glitch. Reprogram the ECM, or replace it if it has failed internally.
Parts you might need
(5)Main Power Relay (Green change-over with diode)
716/09800Used in various JCB electrical circuits
Main Power Relay
716/09500Listed as a relay for various JCB models
T4 Start Relay Jumper
721/X1936Identified as a T4 START RELAY JUMPER
- Start Relay716/06600
Aftermarket replacement start relay for JCB machines
Relay 12V 130A
Found in the electrical parts diagram for a JCB 135 with a T4F engine