JCB P203B-15: DEF Tank Level Signal Exceeds Maximum Voltage Limit
Issue description
The signal from the DEF tank level sensor is registering a voltage that is higher than the maximum allowed limit. This may indicate an issue with the sensor or the circuit it is connected to.
Check the cause
DEF tank level sensor
wiring to the DEF tank level sensor
controller input for DEF tank level signal
Repair steps
Inspect
Inspect the DEF tank level sensor for physical damage or improper installation.
Test
Test the voltage output of the DEF tank level sensor using a multimeter to confirm it is within the expected range.
Check
Check the wiring and connections between the DEF tank level sensor and the controller for any signs of damage, corrosion, or loose connections.
Verify
Verify the controller's input for the DEF tank level signal to ensure it is interpreting the signal correctly.
Parts you might need
(0)Get help to fix this fault by requesting a quote