JCB P203F-21: DEF Tank Head Unit Level Physical Signal Below Minimum Limit
Issue description
The physical signal from the DEF tank head unit indicates that the level is below the minimum limit. This may affect the proper operation of the system relying on this signal.
Check the cause
DEF tank head unit
DEF tank level signal wiring
DEF tank head unit mounting or installation
Repair steps
Inspect
Inspect the DEF tank head unit for proper installation and physical damage.
Check
Check the wiring and connections related to the DEF tank head unit signal.
Verify
Verify the DEF tank level using a manual method to confirm the accuracy of the signal.
Parts you might need