JCB P208C-14: Short Circuit to Ground Error of Supply Module Pump Motor
Issue description
A short circuit to ground has been detected in the supply module pump motor circuit. This fault indicates an electrical issue that may affect the proper operation of the pump motor.
Check the cause
The wiring and connections related to the supply module pump motor
The insulation of the wiring for damage or wear
The supply module pump motor itself for internal faults
Repair steps
Inspect
Inspect the wiring and connections associated with the supply module pump motor for signs of damage, wear, or improper connections.
Test
Test the insulation of the wiring for continuity and resistance to identify any short circuits.
Replace
If a fault is found, replace the damaged wiring or the supply module pump motor as necessary.
Parts you might need
(0)Get help to fix this fault by requesting a quote