JCB P208D-13: Short Circuit to Battery Error of Supply Module Pump Motor
Issue description
A short circuit to battery has been detected in the supply module pump motor circuit. This fault indicates an electrical issue that may affect the proper operation of the pump motor.
Check the cause
The wiring and connections related to the supply module pump motor
The integrity of the supply module pump motor itself
The presence of any damage or wear in the affected circuit
Repair steps
Inspect
Inspect the wiring and connections of the supply module pump motor for signs of damage, wear, or improper connections.
Test
Test the supply module pump motor for continuity and insulation resistance using a multimeter.
Replace
If a fault is found, replace the damaged wiring, connections, or the supply module pump motor as necessary.