P2201-63

JCB P2201-63 – Aftertreatment System ECU: Downstream NOx Sensor Self Diagnostic Timeout

Issue description

The system has detected a timeout during the self-diagnostic test of the downstream NOx sensor. This indicates that the sensor did not complete its internal diagnostic cycle within the expected time frame upon startup. This is classified as a circuit/component protection time-out failure (FMI 31) and affects the exhaust aftertreatment system's ability to monitor emissions.

Applies to these machines

  • Tracked Excavators
  • Wheeled Excavators
  • EcoMAX Tier 4 Engine Machines
  • 406SV Wheel Loader
  • 409SV Wheel Loader
  • Kohler KDI-TC series engines (Stage V)

Check the cause

  1. Visually inspect the downstream NOx sensor wiring harness for chafing, cuts, heat damage, and correct routing

  2. Disconnect the downstream NOx sensor connector and inspect terminals for corrosion, debris, water ingress, or loose/damaged pins

  3. Check the shared power supply and relay for the AdBlue tank and both NOx sensors

  4. Verify machine earth connections are secure and undamaged

  5. Verify the installed NOx sensor's voltage rating (12V or 24V) matches the machine's electrical system

  6. Perform live data analysis comparing upstream and downstream NOx levels; downstream should be significantly lower. Erratic or unresponsive readings indicate a faulty sensor

Repair steps

  1. Rectify Electrical Issues

    If any issues are found with the wiring, connectors, power supply, or grounds during the diagnostic checks, repair or replace the faulty components first. Clear the fault codes and operate the machine to see if the fault returns.

  2. NOx Sensor Replacement

    If all electrical connections and wiring are confirmed to be in good condition, the fault is likely with the downstream NOx sensor itself. The internal failure of the sensor's self-diagnostic is not a repairable condition.

  3. Installation

    When replacing the sensor, ensure the new part is the correct voltage and part number for the specific machine model and serial number.

  4. Clear Codes and Verify Repair

    After replacing the sensor, clear the fault code from the Aftertreatment ECU using a diagnostic tool. Run the machine and check to ensure the P2201-63 fault code does not reappear.

Parts you might need

(5)
  • Downstream NOx Sensor

    0281006533

    Bosch cross-reference (interchangeable with JCB part 320/A9103).

  • Downstream NOx Sensor

    0281006534

    Bosch cross-reference (interchangeable with JCB part 320/A9103).

  • Downstream NOx Sensor

    5WK96755A

    Continental/VDO (5WK9 series) part.

  • Downstream NOx Sensor

    335A2190

    Other OEM part.

Get help to fix this fault by requesting a quote

Browse other JCB codes