P2201-97

JCB P2201-97 – ECU: Downstream NOx Sensor Self Diagnostic Abort

Issue description

The engine's control system has detected an issue during the self-diagnostic test of the downstream Nitrogen Oxide (NOx) sensor, indicating that the diagnostic process did not complete successfully. Located after the Selective Catalytic Reduction (SCR) catalyst, this sensor measures the efficiency of the exhaust gas after-treatment system. A failure in its self-diagnostic routine suggests an obstructed component, a faulty sensor, damaged wiring, or a communication failure with the Engine Control Unit.

Applies to these machines

  • Tracked Excavators
  • Wheeled Excavators
  • Wheel loaders (such as JCB 409)
  • Other equipment using JCB EcoMAX engines

Check the cause

  1. Record and review all fault codes using a diagnostic scanner. Look for related NOx sensor heater circuit, power supply, or communication (U-series) codes.

  2. Inspect the downstream NOx sensor wiring harness for chafing, melting, or breaks, ensuring it is routed away from hot exhaust components.

  3. Disconnect the NOx sensor and ECU connectors to inspect for corrosion (green deposits), moisture, or bent pins. Clean with electrical contact cleaner if needed.

  4. Verify the sensor is receiving the correct voltage (12V or 24V). Check the shared power circuit and relay with the upstream NOx sensor and AdBlue (DEF) tank, and inspect machine earth connections.

  5. Monitor live data from the downstream NOx sensor using a diagnostic tool to check for a frozen or erratic signal.

  6. Inspect the exhaust system for leaks between the upstream and downstream NOx sensors, as leaks can affect sensor readings.

Repair steps

  1. Prepare machine

    Stop the engine, allow the exhaust system to cool completely, and disconnect the vehicle's batteries to prevent electrical hazards.

  2. Remove downstream NOx sensor

    Locate the sensor threaded into the exhaust pipe after the SCR catalyst. Disconnect the electrical connector and unbolt the module bracket if mounted separately. Use a NOx/O2 sensor socket to remove the sensor. If seized, cut the sensor wire to use a standard deep socket.

  3. Clean sensor port

    Clean the threads in the exhaust pipe using an M20 x 1.5 thread chaser to ensure a clean and secure installation.

  4. Install new sensor

    Apply a small amount of anti-seize compound to the threads (avoiding the sensor tip). Thread by hand to avoid cross-threading, then torque to 40-60 Nm. Mount the module, reconnect the electrical connector, and secure the wiring harness using the original clips and ties, ensuring it is routed away from hot or vibrating components.

  5. Finalize repair

    Reconnect batteries and clear all fault codes. Start the engine and perform a road test or run the machine under load to confirm the fault does not return. Run a calibration routine or specific drive cycle via the diagnostic tool if required by the system.

Parts you might need

(5)
  • For Kohler engines. Cross-references Bosch 0281006533 and 0281006534.

  • OEM JCB part.

  • SENSOR NOX

    335/F0989

    OEM JCB part.

  • Nox Sensor 2-3 (Downstream)

    10901016902

    For Rehlko (formerly Kohler) engines.

  • Downstream NOx Sensor

    Bosch replacement options include 0281006533/534, 0281006537/538, 0281006535/536, 0281006505/506. Verify exact part by machine serial number.

Get help to fix this fault by requesting a quote

Browse other JCB codes