JCB P2BAA-94 – Aftertreatment System ECU: Consumption Level1 Requested (Low Reagent)
Issue description
The system has detected a request for Consumption Level1, initiating a 25% engine torque derate. This occurs when the Aftertreatment Control Module detects that nitrogen oxide (NOx) emissions are too high while Diesel Exhaust Fluid (DEF) consumption is too low. The SCR system is not injecting enough DEF to effectively neutralize the NOx emissions, indicating a fault in the DEF delivery or monitoring system.
Applies to these machines
1 machine- EcoMAX Tier 4
Check the cause
Check DEF tank level (ensure it is filled above 30%) and test fluid quality for contamination
Visually inspect all DEF lines and connections between the tank, pump, and injector for leaks, wet spots, or white crystallized DEF buildup
Remove and inspect the DEF injector (doser valve) for clogs caused by crystallized DEF
Inspect wiring harnesses and electrical connectors for the NOx sensors, DEF pump, and DEF injector for damage, corrosion, loose pins, or water ingress
Check the DEF tank sensor head unit to ensure the float moves freely and is not stuck
Verify the machine's ECU and Aftertreatment ECU have the latest software versions installed
Repair steps
Address DEF supply
If the DEF tank is low or fluid is contaminated, fill it with fresh, high-quality DEF from a sealed container.
Clean or replace DEF injector
If the DEF injector is clogged with crystallized DEF, attempt to clean it. If it is damaged or fails to function after cleaning, replace the injector.
Test and replace DEF pump
Using a diagnostic tool, perform a 'DEF Doser Pump Override' or 'Reductant Test' to command the pump to operate. If the pump does not spray fluid, replace it.
Repair DEF leaks
Repair or replace any leaking DEF lines or fittings identified during the visual inspection.
Replace faulty sensors
If diagnostic checks point to a faulty NOx sensor or DEF tank sensor (measuring level, temperature, or quality), replace the affected sensor.
Repair wiring
Repair or replace any damaged sections of the wiring harness or faulty connectors.
Clear codes and verify
After completing repairs, clear the fault codes using a diagnostic tool and operate the machine to ensure the fault does not return.
Parts you might need
(6)- NOx Sensor (12V Short)320/D9836
Measures NOx levels in the exhaust
- NOx Sensor (12V Long)320/D9837
Measures NOx levels in the exhaust
- NOx Sensor320/A9103
Cross-references to Bosch/aftermarket sensor 0281006533
- DEF Pump (Adblue Pump)320/A9100
Pressurizes DEF and sends it to the injector
DEF Pump Filter
400/J4543Located inside the DEF pump assembly
DEF Injector (Doser Valve)
Must be sourced from a JCB dealer using the machine's serial number. Delphi is a known manufacturer.