JCB P2BAD-17 – DCU: Exceeded the Limit Value of Long Term Adaptation Factor
Issue description
The engine's after-treatment system has detected that the long-term adaptation factor for the Diesel Exhaust Fluid (DEF) / AdBlue dosing has exceeded its predefined maximum limit. The Dosing Control Unit (DCU) has had to adjust DEF injection beyond the expected range to maintain required NOx reduction efficiency. This condition triggers a Tier 4 Final inducement, resulting in a reduction of engine power (derate) to encourage immediate service and prevent excessive emissions.
Applies to these machines
18 machines- JS115
- JS130
- JS145
- JS160
- JS180
- JS190
- JS200
- JS210
- JS220
- JS235
- 527
- 535
- 550
- JCB Ecomax Wheeled Loaders
- JCB Ecomax Generators
- JCB Ecomax Lighting Towers
- JCB T4F 444 engine
- JCB T4F 448 engine
Check the cause
Check the DEF (AdBlue) level in the tank to ensure it is not overfilled, which can hinder pressure drop in the return line
Inspect all DEF hoses for kinks, damage, or blockages
Examine electrical connectors at the DCU and dosing module for moisture, corrosion ('green death'), debris, or unsecured pins
Check the machine's primary earth points to ensure they are clean and secure
Check for other active or stored fault codes (e.g., P2201 NOx sensors, P2047 DEF injector circuits, P20EE SCR efficiency) which could be the root cause
Test DEF concentration using a refractometer (should be approximately 32.5%)
Using JCB ServiceMaster, check DCU and ECU software versions (reflash if required) and verify DCU supply voltage (10V-16V for 12V machines, 19V-32V for 24V machines)
Repair steps
Clear fault codes
Clear the DTCs and check if the fault returns immediately.
Perform DEF pump test
Using JCB ServiceMaster, navigate to the DEF pump test and run the procedure. If the test fails, check the DEF harness for continuity and verify the ground connections are clean and tight.
Inspect dosing module and nozzle
Remove the dosing module. Check the injector nozzle for blockage from crystallized DEF and clean if necessary.
Perform dosing quantity test
In ServiceMaster, navigate to the 'DEF dosing quantity test' and run it. If this test fails, the dosing module is likely faulty and should be replaced.
Check for system blockages
If tests indicate pressure issues, check the DEF return line to the tank for any blockages and clear if necessary. Clean all DEF system filters to remove any potential debris.
Replace and initialize components
If the DCU or dosing module is identified as faulty, replace it. If a new dosing module is installed, it is critical to perform the 'dosing module initialisation' procedure using ServiceMaster.
Final confirmation
Clear all fault codes one last time. Perform a key cycle (ignition off for 1-2 minutes) and then operate the machine to ensure the fault does not reappear and that full engine power is restored.
Parts you might need
(5)- Adblue Dosing Control Unit (DCU)320/A9102
Genuine JCB. Also referenced as model DCU-17CV51.
- Dosing Module / DEF Injector320/A9105
Genuine JCB BOSCH Dosing module. Contains the injector nozzle. Replace if dosing quantity test fails.
Fuel Injector
320/06828Delphi. For Ecomax Engine - for reference, NOT the DEF injector. Listed for clarity and to avoid confusion.
- Fuel Injector320/06827
Delphi. For Ecomax Engine - for reference, NOT the DEF injector. Listed for clarity and to avoid confusion.
- Fuel Injector320/06623
Delphi. For Ecomax Engine - for reference, NOT the DEF injector. Listed for clarity and to avoid confusion.