Issue description

The aftertreatment system's operation is detected to be outside of its designed parameters, which the system interprets as potential tampering or a malfunction that compromises emissions control. A Level 2 request signifies a serious or repeated offense. This fault typically triggers a dashboard warning and may result in the engine power being significantly reduced or forced into an idle-only state (no throttle response).

Applies to these machines

  • Tier 4 Final (T4F) engines
  • Stage V engines
  • Ecomax series
  • JS excavators
  • Backhoe loaders
  • Telehandlers

Check the cause

  1. Review other active fault codes related to the SCR/DEF system, such as NOx sensors, DEF quality, DEF injector, or DPF regeneration

  2. Inspect the entire exhaust aftertreatment system for any signs of physical modification, damage, or removal of components

  3. Check the wiring harnesses and connectors for the Aftertreatment ECU, NOx sensors, and DEF system for damage, corrosion, or loose connections

  4. Ensure the Diesel Exhaust Fluid (DEF) tank is filled with high-quality, uncontaminated fluid and is neither low nor overfilled

Repair steps

  1. Connect diagnostic software

    Connect a JCB Service Master or a compatible high-level diagnostic tool to the machine's data link connector.

  2. Read and log all faults

    Read all active and stored fault codes from the Engine and Aftertreatment ECUs to identify the root cause of the tampering fault.

  3. Address primary faults

    Diagnose and repair any other active faults related to the aftertreatment system (e.g., NOx sensor errors, DEF injector circuit faults) before addressing the tampering code.

  4. Check and update ECU software

    Use the JCB Service Master to check if the Aftertreatment ECU software is up to date. If not, flash the ECU with the latest software version using the Flashloader tool. After the update, switch the machine off for at least two minutes before restarting.

  5. Clear fault codes

    Once all underlying issues are resolved and the software is confirmed to be current, use the diagnostic tool to clear all fault codes.

  6. Perform system verification

    Start the machine and run it under normal operating conditions to ensure the fault does not return. A forced DPF regeneration may be required as part of the verification process.

Parts you might need

(4)
  • NOx Sensor

    Common failure point that can trigger aftertreatment faults

  • DEF Injector (Doser)

    Clogged or faulty injector can lead to incorrect DEF dosing

  • DEF Quality Sensor

    Triggers faults if poor quality AdBlue is detected

  • Aftertreatment System ECU

    May require replacement in rare cases of internal failure or if it cannot be reprogrammed