JCB P3416-87 – DCU: Time Out Error for IC1 Frame
Issue description
The Dosing Control Unit (DCU) has detected a timeout error for the IC1 frame, indicating a Missing Message (FMI 87). A specific data message expected from another control unit on the CAN bus network did not arrive within the specified timeframe. This communication breakdown can prevent the proper functioning of the aftertreatment system.
Applies to these machines
8 machines- JCB Ecomax Tier 4 engines
- JS Series Crawler Excavators
- JS Series Wheeled Excavators
- JS130
- JS160
- Backhoe Loaders
- Loadall Telehandlers
- Other equipment utilizing the JCB Tier 4 Final and Tier 4 Interim engines
Check the cause
Check battery voltage and ensure the charging system is functioning correctly, as low system voltage can trigger spurious communication faults
Visually inspect the wiring harness and connectors between the Dosing Control Unit (DCU) and the main Engine ECU for rubbing, fraying, melting, or damage
Disconnect the connectors at the DCU and inspect for corrosion (green or white powder), bent or loose pins, and the presence of water or debris
Verify that all main ground connections for the cab, engine, and chassis are clean, tight, and free from corrosion
Use JCB ServiceMaster to check for other active or historic fault codes, specifically related CAN bus communication codes (U-series) to help pinpoint the network failure
Repair steps
Isolate the Faulty Component
The fault is a communication timeout, so the issue lies in the DCU itself, the wiring to the DCU, or another module on the CAN bus that is failing to send the required message.
Troubleshoot CAN bus
If possible, use JCB ServiceMaster to monitor the CAN bus network and identify which ECU is not communicating. Check the CAN bus termination resistors. A properly terminated CAN bus should have a resistance of approximately 60 ohms when measured across the CAN high and CAN low lines (with the battery disconnected).
Test harness continuity
Perform a point-to-point continuity test on each wire in the harness section connecting the Engine ECU to the Aftertreatment DCU. Check for open circuits (no continuity) and short circuits (continuity to ground or to other wires).
Update software
In some instances, communication issues can be resolved by updating the software for the Engine ECU and the Dosing Control Unit. This requires the JCB ServiceMaster tool.
Replace Dosing Control Unit
If the wiring and connections are confirmed to be in good condition and the software is up to date, the fault may lie with the Dosing Control Unit itself. Replace the DCU and clear the fault codes.
Parts you might need
(7)Listed for various JS-series excavators and Centremount models
Dosing Control Unit (DCU) / Dosing Module
250/A9105Listed as DM 2.5 Dosing Module
Dosing Control Unit (DCU) / Dosing Module
320/B6328Dosing Module Kit for Stage V engines
Engine / Aftertreatment Wiring Harness
320/09890Engine harness for Tier 4 interim 55kW engines
Engine / Aftertreatment Wiring Harness
320/09953Engine harness for Tier 4 Final 56kW engines
Engine / Aftertreatment Wiring Harness
721/E0414Harness Engine Tier 4 Final
Get help to fix this fault by requesting a quote