JCB U059E-02: U059E-02 - CAN bus message error for NO2 level from upstream NOx sensor module number 2
Issue description
The system has detected a CAN bus message error related to the NO2 level reading from the upstream NOx sensor module number 2. This indicates a communication issue with the sensor or its associated circuit.
Check the cause
The connection and wiring of the upstream NOx sensor module number 2
The integrity of the CAN bus communication to the upstream NOx sensor module number 2
The functionality of the component identified by this code
Repair steps
Inspect
Inspect the wiring and connections of the upstream NOx sensor module number 2 for damage, corrosion, or loose contacts.
Test
Test the CAN bus communication to the upstream NOx sensor module number 2 using diagnostic tools to confirm the presence of a communication fault.
Replace
If the fault persists after inspection and testing, replace the component identified by this code.