JCB U059E-29 – Aftertreatment System ECU: CAN Bus Error Upstream NOx Sensor
Issue description
The Aftertreatment System ECU has detected that the data received from the upstream NOx sensor (sensor 'A') over the CAN bus is invalid or interrupted. The '-29' suffix specifically indicates an invalid signal. This communication error means the sensor may be functioning electrically, but its data is not being properly transmitted or interpreted, potentially affecting the accuracy of emissions data. The Engine Control Unit (ECU) may also log a corresponding communication fault.
Applies to these machines
6 machines- EcoMax Series
- Crawler Excavators
- Wheeled Excavators
- Tier 4 Final Engine Machines
- Stage IV Engine Machines
- Stage V Engine Machines
Check the cause
Note the exact fault code and any other active or historic codes, then record and clear the fault code using a diagnostic tool to see if U059E-29 returns immediately
Verify battery voltage and ensure terminals are clean and tight, as low voltage can trigger CAN bus communication codes
Inspect fuses related to the aftertreatment system for any blown fuses that power the NOx sensors
Visually inspect the upstream NOx sensor wiring harness for rubbing, fraying, melting, or other damage
Unplug and inspect the upstream NOx sensor connector for corrosion (green deposits), bent pins, or moisture ingress
Check for damaged, loose, or corroded machine earth/ground connections
Repair steps
Isolate shared faults
Check if both upstream (U059E) and downstream (U059F) NOx sensor codes are present. If so, investigate shared power or ground issues, such as a blown fuse.
Repair harness and connectors
If damage was found during visual inspection, repair the wiring harness or clean/replace connectors. Ensure all connections are secure and sealed against moisture.
Test component wiring and CAN bus
Using a multimeter and the machine's service manual, perform voltage and resistance checks on the sensor's wiring. Use a diagnostic tool like JCB ServiceMaster to monitor CAN bus traffic and verify if the sensor module is communicating.
Replace upstream NOx sensor
If wiring, connectors, and power supply are confirmed good, replace the upstream NOx sensor (the sensor and its integrated control module are typically replaced as a single unit). Clear fault codes after replacement.
Parts you might need
(2)- Upstream NOx Sensor (12V, 400mm)320/A9103
Bosch cross-reference 0281006533 / 0281006534
Upstream NOx Sensor (24V)
320/B9437Verify 12V vs 24V system with machine serial number
Get help to fix this fault by requesting a quote