U059E-62

JCB U059E-62 – ACM: Upstream NOx Sensor NH3 Level CAN Error

Issue description

The Aftertreatment Control Module (ACM) has detected an illogical or unexpected CAN bus message from the upstream NOx sensor regarding the ammonia (NH3) level. This signal comparison failure indicates a communication issue with the sensor or its affected circuit, which can trigger an emissions inducement and lead to an engine power derate.

Applies to these machines

  • 3CX
  • 531-70
  • JS220

Check the cause

  1. Record and clear the fault code using the JCB ServiceMaster tool to determine if the error is an intermittent glitch.

  2. Inspect the upstream NOx sensor wiring harness and aftertreatment CAN bus circuit for chafing, melted insulation, corrosion, or bent pins.

  3. Load-test the batteries (minimum 12.4V for 12V systems or 24.8V for 24V systems) and clean all main battery terminals and ground straps to ensure stable voltage.

  4. Verify CAN bus network integrity by measuring resistance between CAN high and CAN low with the ignition off (should be approximately 60 ohms; 120 ohms indicates a terminating resistor issue or wire break).

  5. Inspect the exhaust system upstream of the NOx sensor for leaks that could introduce excess oxygen and cause irrational sensor data.

Repair steps

  1. Locate and prepare for removal

    Locate the upstream NOx sensor in the exhaust system before the SCR catalyst. Allow the exhaust to cool completely, disconnect the machine's battery, and unplug the sensor's electrical connector.

  2. Remove the faulty NOx sensor

    Unbolt the sensor module from its bracket. Apply penetrating oil to the sensor probe threads. Use a specialized NOx or oxygen sensor socket to carefully remove the probe. If seized, cut the sensor wire and use a standard deep-well socket.

  3. Prepare the exhaust bung

    Clean the threads in the exhaust bung using an M20 x 1.5 thread chaser to ensure the new sensor installs smoothly and seals correctly.

  4. Install the new NOx sensor

    Apply a ceramic-based anti-seize compound to the new sensor's threads (avoiding the tip). Thread the sensor in by hand to prevent cross-threading, tighten to specification, mount the module securely, and reconnect the harness and battery.

  5. Perform system reset and relearn

    Use the JCB ServiceMaster diagnostic tool to clear all fault codes and run the required NOx sensor relearn/adaptation procedure to calibrate the ECU to the new component.

Parts you might need

(4)
  • Upstream NOx Sensor

    400/J8554

    Verify exact part number with dealer using machine serial number.

  • Upstream NOx Sensor

    400/14470
  • Upstream NOx Sensor

    333/W9804
  • Cross-referenced with Bosch P/N 0281006533. Other potential aftermarket cross-references include: 0281006537/538, 0281006535/536, 0281006505/506.

Get help to fix this fault by requesting a quote