U059E-86

JCB U059E-86 – ECU / EEM4 / DCU: CAN Bus Message Error from Upstream NOx Sensor

Issue description

The Engine Control Unit (ECU) has detected invalid or missing data from the upstream NOx sensor via the CAN bus. This sensor measures the concentration of nitrogen oxides in the exhaust gas before it enters the Selective Catalytic Reduction (SCR) system. The ECU relies on this data to accurately calculate the required amount of Diesel Exhaust Fluid (DEF) to inject. A loss of this communication disrupts the emissions aftertreatment process and can trigger engine protection measures.

Applies to these machines

  • Ecomax
  • Dieselmax
  • Tier 4 Final (T4F) engines
  • Stage IV engines
  • T4i 4-cylinder engines
  • T4F 4-cylinder engines

Check the cause

  1. Visually inspect the wiring harness and connectors between the upstream NOx sensor and the ECU for signs of damage, chafing, rubbing against hot exhaust components, burnt sections, or melted plastic.

  2. Disconnect the NOx sensor connector and inspect the terminals for corrosion (green tint), moisture, or pushed-back pins. Ensure the connector securely locks upon re-connection.

  3. Inspect all fuses related to the aftertreatment system and the NOx sensor module.

  4. Using a digital multimeter (DVOM), verify that the NOx sensor module is receiving battery voltage (B+) at the appropriate pins and has a clean, tight ground connection to the chassis.

  5. Perform a CAN Bus health check with power off: measure resistance across CAN High and CAN Low pins (approximately 60 Ohms is healthy; 120 Ohms indicates a missing termination resistor or wiring break; near 0 Ohms indicates a short circuit).

  6. Perform a CAN Bus voltage check with power on: CAN High should be between 2.5V and 4.0V, and CAN Low should be between 1.5V and 2.5V.

Repair steps

  1. Repair wiring and connectors

    If diagnostic checks reveal damaged wiring, corroded connectors, or blown fuses, repair them first. Clean corroded terminals with electrical contact cleaner and apply dielectric grease before reconnecting.

  2. Monitor CAN bus traffic

    If wiring and power supply are good, use a diagnostic tool like JCB ServiceMaster to monitor CAN bus traffic and verify if the NOx sensor is communicating with the ECU.

  3. Clear codes and test operation

    Clear the diagnostic trouble codes from the ECU's memory. Operate the machine to see if the fault code returns.

  4. Replace upstream NOx sensor

    If the U059E-86 code reappears and all wiring/power checks have been exhausted, the upstream NOx sensor assembly is likely faulty and requires replacement.

  5. Perform sensor adaptation

    After installing a new OEM or equivalent NOx sensor, perform an adaptation or reset procedure using a diagnostic tool to ensure the new sensor is correctly calibrated with the ECU.

Parts you might need

(11)
  • Sensor - Nox 12v 400m. Bosch cross-reference: 0281006533 / 0281006534.

  • Upstream NOx Sensor (24V)

    320/B9437

    Bosch cross-reference: 0281008050 / 0281008051.

  • Upstream NOx Sensor (24V)

    320/B9435

    Bosch cross-reference: 0281008048 / 0281008049.

  • Upstream NOx Sensor (Bosch)

    0281006533

    Bosch cross-reference (fits JCB 320/A9103).

  • Upstream NOx Sensor (Bosch)

    0281006534

    Bosch cross-reference (fits JCB 320/A9103).

  • Upstream NOx Sensor (Bosch)

    0281006537

    Other potential Bosch part number.

  • Upstream NOx Sensor (Bosch)

    0281006538

    Other potential Bosch part number.

  • Upstream NOx Sensor (Bosch)

    0281006535

    Other potential Bosch part number.

  • Upstream NOx Sensor (Bosch)

    0281006536

    Other potential Bosch part number.

  • Upstream NOx Sensor (Bosch)

    0281006505

    Other potential Bosch part number.

  • Upstream NOx Sensor (Bosch)

    0281006506

    Other potential Bosch part number.

Get help to fix this fault by requesting a quote

Browse other JCB codes