U059F-02

JCB U059F-02: CAN bus message error for NO2 level from downstream NOx sensor (module number 2)

Issue description

The system has detected a CAN bus message error related to the NO2 level from the downstream NOx sensor. This indicates a communication issue with the sensor or its associated circuit.

Check the cause

  1. The communication link between the downstream NOx sensor and the controller

  2. The wiring and connections associated with the downstream NOx sensor

  3. The functionality of the downstream NOx sensor itself

Repair steps

  1. Inspect

    Inspect the wiring and connections for the downstream NOx sensor for damage, corrosion, or loose connections.

  2. Test

    Test the downstream NOx sensor for proper operation using the appropriate diagnostic tools.

  3. Verify

    Verify the communication between the downstream NOx sensor and the controller using the service manual procedures.