JCB U059F-08 – ECU: Downstream NOx Sensor CAN Error
Issue description
The system has detected a CAN bus message error related to the O2 signal status from the downstream NOx sensor. The Engine Control Unit (ECU) expects to receive data about oxygen levels from the sensor via the CAN bus, but the message is missing, incomplete, or invalid. This indicates a communication issue with the sensor's data transmission, preventing the after-treatment system from correctly monitoring its performance. This fault typically results in a reduction in engine torque and triggers a 'SERVICE' warning to the operator.
Applies to these machines
5 machines- Excavators
- Loaders
- Backhoes
- Tier 4 Engine Machines
- Stage V Engine Machines
Check the cause
Record and clear the code using a diagnostic tool to see if it returns immediately under load (rules out a temporary 'ghost' fault caused by a voltage surge)
Check battery voltage (must test above 12.5V) and inspect ground connections, as weak power can cause CAN bus communication errors
Visually inspect the wiring harness connected to the downstream NOx sensor for rubbing, chafing, melting, or physical damage
Disconnect the NOx sensor module connector and inspect for green corrosion, bent or pushed-out pins, and moisture intrusion
Verify the NOx sensor module is receiving the correct power and has a solid ground connection using a multimeter
Test the CAN bus circuit resistance between CAN High and CAN Low at the OBD port or sensor connector (should be approximately 60 Ohms)
Check CAN bus voltage with the key on and engine off (CAN High should be 2.5-3.5V, CAN Low should be 1.5-2.5V)
Unplug the downstream NOx sensor to see if the fault code changes, which helps isolate whether the fault lies within the sensor itself or the wiring harness
Repair steps
Safety First
Stop the engine and allow the exhaust system to cool completely before starting work. Disconnect the machine's battery to prevent accidental starting.
Locate the Sensor
Identify the downstream NOx sensor. It is screwed into the exhaust pipe after the SCR catalyst. It will have a wiring pigtail leading to a small control module mounted on the machine's frame.
Perform Diagnostics
Complete the diagnostic checks listed in the section above to rule out wiring, power, or network issues. A faulty sensor is often the cause, but these checks prevent unnecessary replacement.
Replace the Sensor
Disconnect the wiring harness from the NOx sensor module. Unbolt the sensor module from the frame. Using the correct size wrench, carefully unscrew the NOx sensor from the exhaust pipe. Apply a small amount of ceramic anti-seize compound to the threads of the new sensor, being careful not to get any on the sensor tip. Install the new sensor and torque it to the manufacturer's specification. Mount the new sensor module to the frame and connect the wiring harness.
Initialization/Reset
For some systems, a reset procedure using a diagnostic tool must be performed after replacing a NOx sensor to initialize the new component with the ECU.
Final Verification
Reconnect the battery, start the engine, and clear any related fault codes. Operate the machine to confirm that the fault code does not return.
Parts you might need
(8)Engine NOx sensor (downstream)
400/J4546Verify fitment by machine serial number
Sensor NOX downstream
400/00829Verify fitment by machine serial number
NOx Sensor
400/14470Verify fitment by machine serial number
- NOx Sensor - 12V Short320/D9836
Verify fitment by machine serial number
- NOx Sensor (Continental)332/J5060
Verify fitment by machine serial number
NOx Sensor (Continental)
332/J5063Verify fitment by machine serial number
NOx Sensor (Continental)
332/J5065Verify fitment by machine serial number
- NOx Sensor (Continental)02/202189
Verify fitment by machine serial number
Get help to fix this fault by requesting a quote