JCB U059F-9A – ECU / ACM: Downstream NOx Sensor CAN Error
Issue description
The system has detected a CAN bus communication failure where the Engine Control Unit (ECU) or Aftertreatment Control Module (ACM) is not receiving a valid heater ratio message from the downstream NOx sensor. The '-9A' suffix indicates that the sensor data is missing, invalid, or outside the expected range. This prevents the aftertreatment system from verifying its operational status and points to a network communication issue with the sensor or the affected circuit rather than a simple electrical short.
Applies to these machines
12 machines- 406 SV
- 407 SV
- 409 SV
- 3CX
- 4CX
- 5CX
- 531-70
- 536-X60AGS
- Kohler KDI-TC 1903E5/26
- Kohler KDI2504
- JCB EcoMAX
- Kohler KDI
Check the cause
Record and clear faults using a diagnostic tool (e.g., JCB ServiceMaster 4) to see if the code returns immediately
Confirm battery voltage is above 12.0V with the engine off, as low voltage can cause CAN bus errors
Inspect the wiring harness between the downstream NOx sensor and the ECU/ACM for rubbing, chafing, melting, or physical damage
Disconnect the downstream NOx sensor connector and inspect for corrosion, bent or backed-out pins, water, or debris, and ensure a secure connection when re-seated
Check that all machine and engine ground straps are clean, tight, and free of corrosion
Perform a CAN bus resistance check at the diagnostic port with the ignition off (a healthy network reads ~60 Ω; 120 Ω indicates an open circuit or missing termination resistor, near 0 Ω indicates a short)
Monitor live CAN bus traffic and downstream NOx sensor data using a diagnostic tool to check for plausible readings for NOx concentration and oxygen levels, identifying static or nonsensical readings
Repair steps
Address basic electrical faults
If diagnostic checks reveal damaged wiring, corroded connectors, or poor power/ground supplies, repair these issues first, then clear codes and re-test.
Isolate the faulty component
If the CAN bus resistance check indicates an open circuit (120 Ω) and external wiring is intact, the fault likely lies within the sensor's internal electronics and terminating resistor.
Replace the downstream NOx sensor
Allow the exhaust to cool, disconnect the electrical connector, and unscrew the sensor. Apply ceramic anti-seize to the threads of the new sensor (avoiding the tip), install, torque to specification, and reconnect.
Perform post-replacement reset
Use a diagnostic tool to perform a system reset or re-learn procedure so the control module recognizes the new sensor. Run a manual DPF regeneration if prompted.