05

John Deere 05: LC2 power 1 at connector X339 is less than 4.0 VDC

Issue description

The power supply for LC2 at connector X339 is below the required 4.0 VDC, which may affect the proper operation of the component connected to this circuit.

Check the cause

  1. The voltage at connector X339 using a multimeter

  2. The wiring and connections to connector X339

  3. The power source supplying LC2

Repair steps

  1. Measure the voltage at connector X339

    Use a multimeter to confirm the voltage level at connector X339.

  2. Inspect the wiring and connections

    Check for any loose, damaged, or corroded wiring and connections at connector X339.

  3. Verify the power source

    Ensure that the power source supplying LC2 is functioning properly and providing the correct voltage.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other John Deere codes